Viessmann · Boiler parts
Viessmann Vitorond 200 VD2A: parts list
97 replacement parts with OEM part numbers for 8 models. Pick your model for a list of only the parts that fit it.
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Top panel, front | 201 | VD2A-125 to VD2A-270 | 1 | |
| Front panel | 202 | VD2A-125 to VD2A-270 | 1 | |
| Side panel (left) | 203 | VD2A-125 to VD2A-270 | 1 | |
| Side panel (right) | 204 | VD2A-125 to VD2A-270 | 1 | |
| Top panel, back | 205 | VD2A-125 to VD2A-270 | 1 | |
| Insulation blanket | 206 | VD2A-125 to VD2A-270 | 1 | |
| Front left cover | 207 | VD2A-125 to VD2A-270 | 1 | |
| Front right cover | 208 | VD2A-125 to VD2A-270 | 1 | |
| Back panel, left | 209 | VD2A-125 to VD2A-270 | 1 | |
| Back panel, right | 210 | VD2A-125 to VD2A-270 | 1 | |
| Insulation blanket, rear | 211 | VD2A-125 to VD2A-270 | 1 | |
| Strain relief (2-channel) | 212 | VD2A-125 to VD2A-270 | 1 | |
| Nameplate Vitorond 200 | 213 | VD2A-125 to VD2A-270 | 1 | |
| Cover, edge molding | 214 | VD2A-125 to VD2A-270 | 1 | |
| Extension bolt, rear | 215 | VD2A-125 to VD2A-270 | 1 | |
| Decorative stripe Not illustrated | 306 | VD2A-125 to VD2A-270 | 1 | |
| Touch-up spray paint Vitotec, silver Not illustrated | 307 | VD2A-125 to VD2A-270 | 1 | |
| Touch-up paint stick Vitotec silver Not illustrated | 308 | VD2A-125 to VD2A-270 | 1 | |
| Technical literature set Not illustrated | 420 | VD2A-125 to VD2A-270 | 1 | |
| Installation Instructions Not illustrated | 421 | VD2A-125 to VD2A-270 | 1 | |
| Start-Up/Service Instructions Not illustrated | 422 | VD2A-125 to VD2A-270 | 1 | |
| Operating Instructions and User's Information Manual Not illustrated | 423 | VD2A-125 to VD2A-270 | 1 | |
| Parts List Not illustrated | 424 | VD2A-125 to VD2A-270 | 1 | |
| Warranty Sheet Cast-Iron Not illustrated | 425 | VD2A-125 to VD2A-270 | 1 | |
| Installation Instructions, Venting System Not illustrated | 426 | VD2A-125 to VD2A-270 | 1 | |
| Installation Supplement Barometric Draft Regulator Not illustrated | 427 | VD2A-125 to VD2A-270 | 1 | |
| Technical Data Sheet, Loctite 55 Not illustrated | 428 | VD2A-125 to VD2A-270 | 1 | |
| Burner/control cable See parts list of control unit | A | VD2A-125 to VD2A-270 | 1 | |
| Boiler control See parts list of control unit | B | VD2A-125 to VD2A-270 | 1 | |
| Rating plate 16-digit bar-coded serial number printed on this plate | C | VD2A-125 to VD2A-270 | 1 | |
| Door hinge | 001 | VD2A-125 to VD2A-270 | 1 | |
| Door hinge stop | 002 | VD2A-125 to VD2A-270 | 1 | |
| Tie rod, M12 | 003 | VD2A-125 to VD2A-270 | 1 | M12 |
| Nipple | 004 | VD2A-125 to VD2A-270 | 1 | d=87 mm |
| Mounting bolt | 005 | VD2A-125 to VD2A-270 | Package of 1 | |
| Rear section (ASME) Order 1 x item 302 per section replaced | 006 | VD2A-125 to VD2A-270 | 1 | |
| Center section (ASME) Order 1 x item 302 per section replaced | 007 | VD2A-125 to VD2A-270 | 1 | |
| Front section (ASME) Order 1 x item 302 per section replaced | 008 | VD2A-125 to VD2A-270 | 1 | |
| Boiler door | 009 | VD2A-125 to VD2A-270 | 1 | |
| Insulation mat | 010 | VD2A-125 to VD2A-270 | 1 | |
| Insulation mat | 011 | VD2A-125 to VD2A-270 | 1 | |
| Glass-fiber gasket rope | 013 | VD2A-125 to VD2A-270 | Length 3000 mm | 20 x 15 mm |
| 4-Point sensor well | 014 | VD2A-125 to VD2A-270 | 1 | |
| Flue gas collector | 015 | VD2A-125 to VD2A-270 | 1 | |
| Barbed hose nipple | 016 | VD2A-125 to VD2A-270 | 1 | 1/4 in. |
| Plastic hose | 017 | VD2A-125 to VD2A-270 | 1 | 800 mm |
| Sight glass c/w gaskets | 018 | VD2A-125 to VD2A-270 | 1 | |
| Sight glass assembly | 019 | VD2A-125 to VD2A-270 | 1 | |
| Burner plate | 020 | VD2A-125 to VD2A-270 | 1 | |
| Plug, 2 in. | 021 | VD2A-125 to VD2A-270 | 1 | 2 in. |
| Cleaning brush handle | 022 | VD2A-125 to VD2A-270 | 1 | |
| Turbulator insert, W2Z a top Applies up to size VD2-195 | 023 | Up to VD2-195 | 1 | |
| Turbulator insert, W2Z b bottom Applies up to size VD2-195 | 024 | Up to VD2-195 | 1 | |
| Gasket | 027 | VD2A-125 to VD2A-270 | 1 | 275 x 275 mm |
| Combustion chamber door refractory Wear part | 012 | VD2A-125 to VD2A-270 | 1 | |
| Cleaning brush head Wear part | 312 | VD2A-125 to VD2A-270 | 1 | 25 x 40 x 100 mm |
| Cleaning brush head Wear part | 313 | VD2A-125 to VD2A-270 | 1 | 50 x 100 x 100 mm |
| Split kit (all sections) | 301 | VD2A-125 to VD2A-270 | 1 | |
| Split kit (1 section) For pos. 006, 007, 008 | 302 | VD2A-125 to VD2A-270 | 1 | |
| Soudal gasket seal | 303 | VD2A-125 to VD2A-270 | Tube | 310 ml |
| Accessory pack for insulation | 305 | VD2A-125 to VD2A-270 | 1 | |
| Extension rod | 028 | VD2A-125 to VD2A-270 | 1 | M10 355 mm |
| Plastic hose assembly | 030 | VD2A-125 to VD2A-270 | 1 | |
| Bolt | 031 | VD2A-125 to VD2A-270 | 1 | |
| Insulation blanket | 032 | VD2A-125 to VD2A-270 | 1 | d=240 mm |
| Gasket DN65 PN6 | 033 | VD2A-125 to VD2A-270 | 1 | DN65 PN6 |
| Cleanout cover | 034 | VD2A-125 to VD2A-270 | 1 | |
| Glass-fiber gasket | 035 | VD2A-125 to VD2A-270 | 1 | 10 x 10 x 1000 mm |
| Fiber rope seal | 036 | VD2A-125 to VD2A-270 | 1 | 12 x 12 x 3000 mm |
| Accessory pack for return distribution tube | 037 | VD2A-125 to VD2A-270 | 1 | |
| Gasket | 038 | VD2A-125 to VD2A-270 | 1 | 60 x 116 x 3 mm |
| Flange | 039 | VD2A-125 to VD2A-270 | 1 | |
| Gasket for return distribution | 041 | VD2A-125 to VD2A-270 | 1 | 62 x 95 x 3 mm |
| Gasket | 351 | VD2A-125 to VD2A-270 | 1 | DN40 PN6 |
| Installation fittings assembly | 400 | VD2A-125 to VD2A-270 | 1 | |
| Pressure gage | 401 | VD2A-125 to VD2A-270 | 1 | 0-160 psi, 2.5 |
| Pressure relief valve | 402 | VD2A-125 to VD2A-270 | 1 | |
| Low water cutoff | 404 | VD2A-125 to VD2A-270 | 1 | |
| Thermometer | 405 | VD2A-125 to VD2A-270 | 1 | |
| Air vent | 406 | VD2A-125 to VD2A-270 | 1 | e in. |
| Flange | 408 | VD2A-125 to VD2A-270 | 1 | DN2631 PN6, 2 1/2 in. NPT |
| Plug | 409 | VD2A-125 to VD2A-270 | 1 | 3/4 in. BSPT BMI |
| Gasket | 350 | VD2A-125 to VD2A-270 | 1 | 41 x 56 x 2 mm |
| Loctite 55 pipe sealing cord Other part, not illustrated | 403 | VD2A-125 to VD2A-270 | Length 12 m | 39 ft. |
| Gasket | 033 | All 8 models | 1 | |
| Gasket, 60 x 116 x 3 mm | 038 | All 8 models | 1 | 60 x 116 x 3 mm |
| Gasket, DN40 PN6 | 351 | All 8 models | 1 | DN40 PN6 |
| Gasket, 41 x 56 x 2 mm Other part, not illustrated. | 350 | All 8 models | 1 | 41 x 56 x 2 mm |
| Installation fittings assembly | 400 | All 8 models | 1 | |
| Pressure gage | 401 | All 8 models | 1 | 0-160 psi, 2.5 |
| Pressure relief valve Do not install any valve between this valve and the boiler. | 402 | All 8 models | 1 | |
| Low water cutoff | 404 | All 8 models | 1 | |
| Thermometer | 405 | All 8 models | 1 | |
| Air vent | 406 | All 8 models | 1 | |
| Flange, 2½ in. NPT | 408 | All 8 models | 1 | DN2631 PN6, 2½ in. NPT |
| Plug, BSPT | 409 | All 8 models | 1 | ¾ in. BSPT |
| Loctite 55 pipe sealing cord Other part, not illustrated. | 403 | All 8 models | 1 roll | 39 ft (12 m) |
Source: Vitorond 200 VD2A service instructions, p. 18 (pages 17, 18, 19, 22). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.