Viessmann · Boiler · Vitorond 200 VD2A series

VD2A-125 to VD2A-270 parts

95 replacement parts that fit the Viessmann VD2A-125 to VD2A-270, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Top panel, front2011
Front panel2021
Side panel (left)2031
Side panel (right)2041
Top panel, back2051
Insulation blanket2061
Front left cover2071
Front right cover2081
Back panel, left2091
Back panel, right2101
Insulation blanket, rear2111
Strain relief (2-channel)2121
Nameplate Vitorond 2002131
Cover, edge molding2141
Extension bolt, rear2151
Decorative stripe
Not illustrated
3061
Touch-up spray paint Vitotec, silver
Not illustrated
3071
Touch-up paint stick Vitotec silver
Not illustrated
3081
Technical literature set
Not illustrated
4201
Installation Instructions
Not illustrated
4211
Start-Up/Service Instructions
Not illustrated
4221
Operating Instructions and User's Information Manual
Not illustrated
4231
Parts List
Not illustrated
4241
Warranty Sheet Cast-Iron
Not illustrated
4251
Installation Instructions, Venting System
Not illustrated
4261
Installation Supplement Barometric Draft Regulator
Not illustrated
4271
Technical Data Sheet, Loctite 55
Not illustrated
4281
Burner/control cable
See parts list of control unit
A1
Boiler control
See parts list of control unit
B1
Rating plate
16-digit bar-coded serial number printed on this plate
C1
Door hinge0011
Door hinge stop0021
Tie rod, M120031M12
Nipple0041d=87 mm
Mounting bolt005Package of 1
Rear section (ASME)
Order 1 x item 302 per section replaced
0061
Center section (ASME)
Order 1 x item 302 per section replaced
0071
Front section (ASME)
Order 1 x item 302 per section replaced
0081
Boiler door0091
Insulation mat0101
Insulation mat0111
Glass-fiber gasket rope013Length 3000 mm20 x 15 mm
4-Point sensor well0141
Flue gas collector0151
Barbed hose nipple01611/4 in.
Plastic hose0171800 mm
Sight glass c/w gaskets0181
Sight glass assembly0191
Burner plate0201
Plug, 2 in.02112 in.
Cleaning brush handle0221
Gasket0271275 x 275 mm
Combustion chamber door refractory
Wear part
0121
Cleaning brush head
Wear part
312125 x 40 x 100 mm
Cleaning brush head
Wear part
313150 x 100 x 100 mm
Split kit (all sections)3011
Split kit (1 section)
For pos. 006, 007, 008
3021
Soudal gasket seal303Tube310 ml
Accessory pack for insulation3051
Extension rod0281M10 355 mm
Plastic hose assembly0301
Bolt0311
Insulation blanket0321d=240 mm
Gasket DN65 PN60331DN65 PN6
Cleanout cover0341
Glass-fiber gasket035110 x 10 x 1000 mm
Fiber rope seal036112 x 12 x 3000 mm
Accessory pack for return distribution tube0371
Gasket038160 x 116 x 3 mm
Flange0391
Gasket for return distribution041162 x 95 x 3 mm
Gasket3511DN40 PN6
Installation fittings assembly4001
Pressure gage40110-160 psi, 2.5
Pressure relief valve4021
Low water cutoff4041
Thermometer4051
Air vent4061e in.
Flange4081DN2631 PN6, 2 1/2 in. NPT
Plug40913/4 in. BSPT BMI
Gasket350141 x 56 x 2 mm
Loctite 55 pipe sealing cord
Other part, not illustrated
403Length 12 m39 ft.
Gasket0331
Gasket, 60 x 116 x 3 mm038160 x 116 x 3 mm
Gasket, DN40 PN63511DN40 PN6
Gasket, 41 x 56 x 2 mm
Other part, not illustrated.
350141 x 56 x 2 mm
Installation fittings assembly4001
Pressure gage40110-160 psi, 2.5
Pressure relief valve
Do not install any valve between this valve and the boiler.
4021
Low water cutoff4041
Thermometer4051
Air vent4061
Flange, 2½ in. NPT4081DN2631 PN6, 2½ in. NPT
Plug, BSPT4091¾ in. BSPT
Loctite 55 pipe sealing cord
Other part, not illustrated.
4031 roll39 ft (12 m)

Same series

The Vitorond 200 VD2A parts list shows every part for all 8 models side by side. Other models: Up to VD2-195, VD2A 125 to 270, VD2A-125, VD2A-160, VD2A-195, VD2A-230, VD2A-270.

Source: Vitorond 200 VD2A service instructions, p. 18 (pages 17, 18, 19, 22). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.