Viessmann · Boiler · Vitodens 100-W series

WB1B 26 parts

76 replacement parts that fit the Viessmann WB1B 26, with OEM part numbers, grouped by system.

Condensate

PartPart #QtySize / rating
Condensate pipe0171
Condensate hose0181

Other

PartPart #QtySize / rating
Gas connection pipe0071
Front panel0221
Burner gasket0501d=187 x 5.5 mm
Combustion chamber door refractory0511
Burner tube0521
Gasket for burner tube0531
Ignition and ionization electrode block0541
Gasket for electrode block0551
Radial fan NRG118-CVI0561120/1/60
Gas valve / Venturi assembly0571120/1/60
Burner mounting flange assembly0581
Venturi extension0591
Gasket for radial fan0601
Gasket set for gas connection pipe0611
Gasket set for gas valve / Venturi assembly0621
Flip-down cover0871
Hinges for control housing (set of 10)
Other part, not illustrated
09010
Touch-up spray paint Vitowhite
Other part, not illustrated
1071
Touch-up paint stick Vitowhite
Other part, not illustrated
1081
Conversion kit NG to LPG
Other part, not illustrated
1091
Conversion kit LPG to NG
Other part, not illustrated
1101
Heat exchanger assembly, ASME0011
Heat exchanger connection pipe (supply)0021
Heat exchanger connection pipe (return)0031
Spring clips (set)0041
Fastener set (return pipe)0061
Vent pipe adaptor0091
P-Trap0101
Gasket for flue gases0111
Air intake cover0121
Air intake cap0131
Test port cap (set of 2)0142
Wall-mount bracket0151
Combustion chamber refractory0161
Gasket for air intake0191
Guide rails (set of 2)0202
Clip (set of 5)0215d=8
Connector retaining clip (set of 2)0232
Sealing grommet0241DN60
O-ring set for heat exchanger025121 x 3 mm
Sealing grommet set0261
Air vent with shut-off base0271
Supply/return O-ring set028118 x 3 mm
Support bracket set for heat exchanger0291
Heating supply connection pipe0301
Heating return connection pipe0311
Heating return connection elbow incl. air vent (027)0701
Fixed high limit0821210 F (99 C)
Boiler sensor0831
Flue gas sensor0841
Flow switch VK315M0881
Pressure gauge (PSI)0081PSI
Control console0801
Control console cover0811
Fuse for control console 080 (pkg of 10)085102.5 A / 250 V
Power/pump control module0861
Fuse for power/pump control module 086 (pkg of 10)
Other part, not illustrated
089106.3 A / 250 V
Control bracket
Other part, not illustrated
0631
Wiring harness X20
Other part, not illustrated
1011
Connecting cable No. 35 for gas valve
Other part, not illustrated
1021
Connecting cable No. 100 for radial fan
Other part, not illustrated
1031
Connecting cable for ignitor
Other part, not illustrated
1041
Strain relief
Other part, not illustrated
1051
Grounding wire for ignition electrode
Other part, not illustrated
1061
Pressure relief valve04141
Nipple04021
Sediment faucet04031
Tee04041
Nipple04051
Gas ball valve04061
Extension04071
Accessory pack (metal stud mount kit)
Other part, not illustrated
04101
Outdoor temperature sensor
Other part, not illustrated
04131
Temperature gauge 30-250 F
Install anywhere in supply piping near boiler
041612 in, 30-250 F

Same series

The Vitodens 100-W parts list shows every part for all 7 models side by side. Other models: 26c, 35, 35c, WB1A, WB1B, WB1B 26c.

Source: Vitodens 100-W WB1B installation and service instructions (pages 93, 94, 95). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.