Viessmann · Boiler · Vitodens 100-W series
35c parts
95 replacement parts that fit the Viessmann 35c, with OEM part numbers, grouped by system.
Condensate
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Gas connection pipe | 007 | 1 | |
| Front panel | 022 | 1 | |
| Burner gasket | 050 | 1 | d=187 x 5.5 mm |
| Combustion chamber door refractory | 051 | 1 | |
| Burner tube | 052 | 1 | |
| Gasket for burner tube | 053 | 1 | |
| Ignition and ionization electrode block | 054 | 1 | |
| Gasket for electrode block | 055 | 1 | |
| Radial fan NRG118-CVI | 056 | 1 | 120/1/60 |
| Gas valve / Venturi assembly | 057 | 1 | 120/1/60 |
| Burner mounting flange assembly | 058 | 1 | |
| Venturi extension | 059 | 1 | |
| Gasket for radial fan | 060 | 1 | |
| Gasket set for gas connection pipe | 061 | 1 | |
| Gasket set for gas valve / Venturi assembly | 062 | 1 | |
| Flip-down cover | 087 | 1 | |
| Hinges for control housing (set of 10) Other part, not illustrated | 090 | 10 | |
| Touch-up spray paint Vitowhite Other part, not illustrated | 107 | 1 | |
| Touch-up paint stick Vitowhite Other part, not illustrated | 108 | 1 | |
| Conversion kit NG to LPG Other part, not illustrated | 109 | 1 | |
| Conversion kit LPG to NG Other part, not illustrated | 110 | 1 | |
| Heat exchanger assembly, ASME | 001 | 1 | |
| Heat exchanger connection pipe (supply) | 002 | 1 | |
| Heat exchanger connection pipe (return) | 003 | 1 | |
| Spring clips (set) | 004 | 1 | |
| Fastener set (return pipe) | 006 | 1 | |
| Vent pipe adaptor | 009 | 1 | |
| P-Trap | 010 | 1 | |
| Gasket for flue gases | 011 | 1 | |
| Air intake cover | 012 | 1 | |
| Air intake cap | 013 | 1 | |
| Test port cap (set of 2) | 014 | 2 | |
| Wall-mount bracket | 015 | 1 | |
| Combustion chamber refractory | 016 | 1 | |
| Gasket for air intake | 019 | 1 | |
| Guide rails (set of 2) | 020 | 2 | |
| Clip (set of 5) | 021 | 5 | d=8 |
| Connector retaining clip (set of 2) | 023 | 2 | |
| Sealing grommet | 024 | 1 | DN60 |
| O-ring set for heat exchanger | 025 | 1 | 21 x 3 mm |
| Sealing grommet set | 026 | 1 | |
| Air vent with shut-off base | 027 | 1 | |
| Supply/return O-ring set | 028 | 1 | 18 x 3 mm |
| Support bracket set for heat exchanger | 029 | 1 | |
| Heating supply connection pipe | 030 | 1 | |
| Heating return connection pipe | 031 | 1 | |
| Heating return connection elbow incl. air vent (027) | 070 | 1 | |
| Fixed high limit | 082 | 1 | 210 F (99 C) |
| Boiler sensor | 083 | 1 | |
| Flue gas sensor | 084 | 1 | |
| Flow switch VK315M | 088 | 1 | |
| Pressure gauge (PSI) | 008 | 1 | PSI |
| Control console | 080 | 1 | |
| Control console cover | 081 | 1 | |
| Fuse for control console 080 (pkg of 10) | 085 | 10 | 2.5 A / 250 V |
| Power/pump control module | 086 | 1 | |
| Fuse for power/pump control module 086 (pkg of 10) Other part, not illustrated | 089 | 10 | 6.3 A / 250 V |
| Control bracket Other part, not illustrated | 063 | 1 | |
| Wiring harness X20 Other part, not illustrated | 101 | 1 | |
| Connecting cable No. 35 for gas valve Other part, not illustrated | 102 | 1 | |
| Connecting cable No. 100 for radial fan Other part, not illustrated | 103 | 1 | |
| Connecting cable for ignitor Other part, not illustrated | 104 | 1 | |
| Strain relief Other part, not illustrated | 105 | 1 | |
| Grounding wire for ignition electrode Other part, not illustrated | 106 | 1 | |
| Pressure relief valve | 0414 | 1 | |
| Nipple | 0402 | 1 | |
| Sediment faucet | 0403 | 1 | |
| Tee | 0404 | 1 | |
| Nipple | 0405 | 1 | |
| Gas ball valve | 0406 | 1 | |
| Extension | 0407 | 1 | |
| Accessory pack (metal stud mount kit) Other part, not illustrated | 0410 | 1 | |
| Outdoor temperature sensor Other part, not illustrated | 0413 | 1 | |
| Temperature gauge 30-250 F Install anywhere in supply piping near boiler | 0416 | 1 | 2 in, 30-250 F |
| Cover panel | 010 | 1 | |
| Bottom panel | 020 | 1 | |
| Nipple | 101 | 1 | 3/4 in HEX |
| Flex pipe | 102 | 1 | 3/4 in x 7 in |
| Flex pipe | 103 | 1 | 3/4 in x 12 in |
| Connectors with clips and O-rings (set of 2) | 104 | 2 | |
| Sealing grommet | 105 | 1 | |
| Accessory pack, anchors (set of 4) | 106 | 4 | |
| Pressure relief valve | 107 | 1 | 3/4 in, 150 psig |
| Tee, brass | 108 | 1 | 3/4 in |
| Gaskets assortment | 109 | 1 | 3/8 in, 3/4 in |
| Adaptor, G to NPT | 110 | 1 | G x NPT (size garbled in source) |
| Adaptor, G to NPT | 111 | 1 | G x NPT (size garbled in source) |
| Harness for sensors | 200 | 1 | |
| Harness for pump | 201 | 1 | |
| Accessory pack, conduit clips (set of 2) | 202 | 2 | |
| Installation fittings complete set (items 101 to 111 and 390) Other part, not illustrated | 100 | 1 | |
| Touch-up spray paint Vitowhite Other part, not illustrated | 404 | 1 | |
| Touch-up paint stick Vitowhite Other part, not illustrated | 405 | 1 |
Same series
The Vitodens 100-W parts list shows every part for all 7 models side by side. Other models: 26c, 35, WB1A, WB1B, WB1B 26, WB1B 26c.
Source: Vitodens 100-W WB1B installation and service instructions (pages 93, 94, 95, 96). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.