Viessmann Vitodens 100-W: parts list

95 replacement parts with OEM part numbers for 7 models. Pick your model for a list of only the parts that fit it.

Jump to: Condensate · Other

Condensate

PartPart #FitsQtySize / rating
Condensate pipe017WB1B 26, 35, 26c, 35c1
Condensate hose018WB1B 26, 35, 26c, 35c1

Other

PartPart #FitsQtySize / rating
Gas connection pipe007WB1B 26, 35, 26c, 35c1
Front panel022WB1B 26, 35, 26c, 35c1
Burner gasket050WB1B 26, 35, 26c, 35c1d=187 x 5.5 mm
Combustion chamber door refractory051WB1B 26, 35, 26c, 35c1
Burner tube052WB1B 26, 35, 26c, 35c1
Gasket for burner tube053WB1B 26, 35, 26c, 35c1
Ignition and ionization electrode block054WB1B 26, 35, 26c, 35c1
Gasket for electrode block055WB1B 26, 35, 26c, 35c1
Radial fan NRG118-CVI056WB1B 26, 35, 26c, 35c1120/1/60
Gas valve / Venturi assembly057WB1B 26, 35, 26c, 35c1120/1/60
Burner mounting flange assembly058WB1B 26, 35, 26c, 35c1
Venturi extension059WB1B 26, 35, 26c, 35c1
Gasket for radial fan060WB1B 26, 35, 26c, 35c1
Gasket set for gas connection pipe061WB1B 26, 35, 26c, 35c1
Gasket set for gas valve / Venturi assembly062WB1B 26, 35, 26c, 35c1
Flip-down cover087WB1B 26, 35, 26c, 35c1
Hinges for control housing (set of 10)
Other part, not illustrated
090WB1B 26, 35, 26c, 35c10
Touch-up spray paint Vitowhite
Other part, not illustrated
107WB1B 26, 35, 26c, 35c1
Touch-up paint stick Vitowhite
Other part, not illustrated
108WB1B 26, 35, 26c, 35c1
Conversion kit NG to LPG
Other part, not illustrated
109WB1B 26, 35, 26c, 35c1
Conversion kit LPG to NG
Other part, not illustrated
110WB1B 26, 35, 26c, 35c1
Heat exchanger assembly, ASME001WB1B 26, 35, 26c, 35c1
Heat exchanger connection pipe (supply)002WB1B 26, 35, 26c, 35c1
Heat exchanger connection pipe (return)003WB1B 26, 35, 26c, 35c1
Spring clips (set)004WB1B 26, 35, 26c, 35c1
Fastener set (return pipe)006WB1B 26, 35, 26c, 35c1
Vent pipe adaptor009WB1B 26, 35, 26c, 35c1
P-Trap010WB1B 26, 35, 26c, 35c1
Gasket for flue gases011WB1B 26, 35, 26c, 35c1
Air intake cover012WB1B 26, 35, 26c, 35c1
Air intake cap013WB1B 26, 35, 26c, 35c1
Test port cap (set of 2)014WB1B 26, 35, 26c, 35c2
Wall-mount bracket015WB1B 26, 35, 26c, 35c1
Combustion chamber refractory016WB1B 26, 35, 26c, 35c1
Gasket for air intake019WB1B 26, 35, 26c, 35c1
Guide rails (set of 2)020WB1B 26, 35, 26c, 35c2
Clip (set of 5)021WB1B 26, 35, 26c, 35c5d=8
Connector retaining clip (set of 2)023WB1B 26, 35, 26c, 35c2
Sealing grommet024WB1B 26, 35, 26c, 35c1DN60
O-ring set for heat exchanger025WB1B 26, 35, 26c, 35c121 x 3 mm
Sealing grommet set026WB1B 26, 35, 26c, 35c1
Air vent with shut-off base027WB1B 26, 35, 26c, 35c1
Supply/return O-ring set028WB1B 26, 35, 26c, 35c118 x 3 mm
Support bracket set for heat exchanger029WB1B 26, 35, 26c, 35c1
Heating supply connection pipe030WB1B 26, 35, 26c, 35c1
Heating return connection pipe031WB1B 26, 35, 26c, 35c1
Heating return connection elbow incl. air vent (027)070WB1B 26, 35, 26c, 35c1
Fixed high limit082WB1B 26, 35, 26c, 35c1210 F (99 C)
Boiler sensor083WB1B 26, 35, 26c, 35c1
Flue gas sensor084WB1B 26, 35, 26c, 35c1
Flow switch VK315M088WB1B 26, 35, 26c, 35c1
Pressure gauge (PSI)008WB1B 26, 35, 26c, 35c1PSI
Control console080WB1B 26, 35, 26c, 35c1
Control console cover081WB1B 26, 35, 26c, 35c1
Fuse for control console 080 (pkg of 10)085WB1B 26, 35, 26c, 35c102.5 A / 250 V
Power/pump control module086WB1B 26, 35, 26c, 35c1
Fuse for power/pump control module 086 (pkg of 10)
Other part, not illustrated
089WB1B 26, 35, 26c, 35c106.3 A / 250 V
Control bracket
Other part, not illustrated
063WB1B 26, 35, 26c, 35c1
Wiring harness X20
Other part, not illustrated
101WB1B 26, 35, 26c, 35c1
Connecting cable No. 35 for gas valve
Other part, not illustrated
102WB1B 26, 35, 26c, 35c1
Connecting cable No. 100 for radial fan
Other part, not illustrated
103WB1B 26, 35, 26c, 35c1
Connecting cable for ignitor
Other part, not illustrated
104WB1B 26, 35, 26c, 35c1
Strain relief
Other part, not illustrated
105WB1B 26, 35, 26c, 35c1
Grounding wire for ignition electrode
Other part, not illustrated
106WB1B 26, 35, 26c, 35c1
Pressure relief valve0414WB1B 26, 35, 26c, 35c1
Nipple0402WB1B 26, 35, 26c, 35c1
Sediment faucet0403WB1B 26, 35, 26c, 35c1
Tee0404WB1B 26, 35, 26c, 35c1
Nipple0405WB1B 26, 35, 26c, 35c1
Gas ball valve0406WB1B 26, 35, 26c, 35c1
Extension0407WB1B 26, 35, 26c, 35c1
Accessory pack (metal stud mount kit)
Other part, not illustrated
0410WB1B 26, 35, 26c, 35c1
Outdoor temperature sensor
Other part, not illustrated
0413WB1B 26, 35, 26c, 35c1
Temperature gauge 30-250 F
Install anywhere in supply piping near boiler
0416WB1B 26, 35, 26c, 35c12 in, 30-250 F
Cover panel010WB1B 26c, 35c1
Bottom panel020WB1B 26c, 35c1
Nipple101WB1B 26c, 35c13/4 in HEX
Flex pipe102WB1B 26c, 35c13/4 in x 7 in
Flex pipe103WB1B 26c, 35c13/4 in x 12 in
Connectors with clips and O-rings (set of 2)104WB1B 26c, 35c2
Sealing grommet105WB1B 26c, 35c1
Accessory pack, anchors (set of 4)106WB1B 26c, 35c4
Pressure relief valve107WB1B 26c, 35c13/4 in, 150 psig
Tee, brass108WB1B 26c, 35c13/4 in
Gaskets assortment109WB1B 26c, 35c13/8 in, 3/4 in
Adaptor, G to NPT110WB1B 26c, 35c1G x NPT (size garbled in source)
Adaptor, G to NPT111WB1B 26c, 35c1G x NPT (size garbled in source)
Harness for sensors200WB1B 26c, 35c1
Harness for pump201WB1B 26c, 35c1
Accessory pack, conduit clips (set of 2)202WB1B 26c, 35c2
Installation fittings complete set (items 101 to 111 and 390)
Other part, not illustrated
100WB1B 26c, 35c1
Touch-up spray paint Vitowhite
Other part, not illustrated
404WB1B 26c, 35c1
Touch-up paint stick Vitowhite
Other part, not illustrated
405WB1B 26c, 35c1

Source: Vitodens 100-W WB1B installation and service instructions (pages 93, 94, 95, 96). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.