Viessmann · Boiler parts
Viessmann Vitotronic 200: parts list
41 replacement parts with OEM part numbers for 4 models. Pick your model for a list of only the parts that fit it.
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Cable clip | 001 | KW2 | 1 | |
| Adjustable high limit dial | 004 | KW2 | 1 | |
| Cover for fixed high limit | 005 | KW2 | 1 | |
| Front flip-down cover | 010 | KW2 | 1 | |
| Control panel, bottom right | 011 | KW2 | 1 | |
| Housing, top (drawer) | 013 | KW2 | 1 | |
| Circuit board cover assembly | 014 | KW2 | 1 | |
| Flip-down cover of programming unit | 015 | KW2 | 1 | |
| Housing, bottom | 016 | KW2 | 1 | |
| Control housing, rear | 017 | KW2 | 1 | |
| Programming unit | 018 | KW2 | 1 | |
| Front cover for heating circuit selector buttons | 019 | KW2 | 1 | |
| Flat cable, 14-pole | 020 | KW2 | 1 | 14-pole |
| Fuse holder | 023 | KW2 | 1 | |
| Fuse holder cover | 024 | KW2 | 1 | |
| Fixed high limit | 030 | KW2 | 1 | 230 °F (212 °F) / 110 °C (100 °C) |
| Adjustable high limit | 031 | KW2 | 1 | |
| Adjustable high limit rotary knob | 033 | KW2 | 1 | |
| Switch, 1-pole (FHL test switch) | 035 | KW2 | 1 | |
| Switch, 2-pole (ON/OFF switch) | 036 | KW2 | 1 | |
| Outdoor temperature sensor | 040 | KW2 | 1 | |
| Supply temperature sensor with plug-in connector | 041 | KW2 | 1 | |
| Boiler temperature sensor with plug-in connector | 042 | KW2 | 1 | |
| DHW tank temperature sensor with plug-in connector | 043 | KW2 | 1 | |
| Circuit board control (software) | 050 | KW2 | 1 | |
| Optolink circuit board | 051 | KW2 | 1 | |
| Motherboard | 052 | KW2 | 1 | |
| Power supply circuit board | 054 | KW2 | 1 | |
| Control cable | 065 | KW2 | 1 | |
| Connecting cable | 074 | KW2 | 1 | |
| Fuse T 4 A / 250 VAC | 090 | KW2 | 1 | T 4 A / 250 VAC |
| Fuse T 6.3 A / 250 VAC | 091 | KW2 | 1 | T 6.3 A / 250 VAC |
| Fuse holder | 092 | KW2 | 1 | |
| Pack of strain relief clamp parts | 098 | KW2 | 1 | |
| Pack of mounting screws Other part, not illustrated | 099 | KW2 | 1 | |
| Power/Pump Module Other part, not illustrated | 120 | KW2 | 1 | |
| Installation Instructions Other part, not illustrated | 121 | KW2 | 1 | |
| Service Instructions Other part, not illustrated | 122 | KW2 | 1 | |
| Operating Instructions Other part, not illustrated | 123 | KW2 | 1 | |
| Parts List Other part, not illustrated | 124 | KW2 | 1 | |
| Rating plate Needed model and serial number when ordering parts | A | KW2 | 1 |
Source: Vitotronic 200 Model KW2 service instructions, p. 103 (page 103). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.