| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Door hinge | 001 | All VD2 sizes | 1 | |
| Tie rod, 24 in. (610 mm) | 002 | All VD2 sizes | 1 | 24 in. (610 mm) |
| Tie rod, 19 in. (480 mm) | 003 | All VD2 sizes | 1 | 19 in. (480 mm) |
| Push nipple | 004 | All VD2 sizes | 1 | |
| Fiber rope seal Glue for this seal is item 304 | 005 | All VD2 sizes | 1 | 7.5 in. (12 mm) |
| Door hinge, stop | 006 | All VD2 sizes | 1 | |
| Intermediate section Order item 306 for every section joint | 007 | All VD2 sizes | 1 | |
| Front section Order item 306 for every section joint | 008 | All VD2 sizes | 1 | |
| Combustion chamber door | 009 | All VD2 sizes | 1 | |
| Insulation blanket | 010 | All VD2 sizes | 1 | 18.5 x 18.5 in. (467 x 467 mm) |
| Insulation blanket (three part) | 011 | All VD2 sizes | 1 | 34 x 38 in. (868 x 968 mm) |
| Combustion chamber door insulation block | 012 | All VD2 sizes | 1 | |
| Fiber rope seal | 013 | All VD2 sizes | 1 | 5/8 x 5/8 in. (16 x 16 mm) |
| Hose nipple | 014 | All VD2 sizes | 1 | 1/4 in. (6 mm) |
| Plastic hose | 015 | All VD2 sizes | 1 | 31.5 in. (800 mm) |
| Sight glass c/w gasket | 016 | All VD2 sizes | 1 | |
| Sight glass cover | 017 | All VD2 sizes | 1 | |
| Burner plate | 018 | All VD2 sizes | 1 | |
| Turbulator insert | 019 | VD2-320 to VD2-860 | Per third flue: 3 (VD2-320 to 440); 2 (VD2-500 to 560); 1 (VD2-630 to 860) | |
| Gasket | 020 | All VD2 sizes | 1 | 1.5 x 1.75 x 1/10 in. (35 x 45 x 2 mm) |
| Gasket | 021 | All VD2 sizes | 1 | 7.25 in. (8 mm) |
| Plug | 022 | All VD2 sizes | 1 | 2 in. (51 mm) |
| Insulation blanket | 023 | All VD2 sizes | 1 | 7/16 in. (408 mm) |
| Fiber rope seal | 024 | All VD2 sizes | 1 | 7.5 in. (10 mm) |
| Accessory pack (insulation) | 300 | All VD2 sizes | 1 | |
| Decorative stripe | 301 | All VD2 sizes | 1 | 1 roll = 33 ft (10 m) |
| Touch-up spray paint, Vitosilver | 302 | All VD2 sizes | 1 | |
| Touch-up paint stick, Vitosilver | 303 | All VD2 sizes | 1 | |
| Glue for sealant rope For position 005 | 304 | All VD2 sizes | 1 | 150 ml |
| Split kit For positions 007, 008 and 025 | 306 | All VD2 sizes | 1 per section joint | |
| Installation Instructions Literature | 307 | All VD2 sizes | 1 | |
| Service Instructions Literature | 308 | All VD2 sizes | 1 | |
| Operating Instructions and User's Information Manual Literature | 309 | All VD2 sizes | 1 |
Source: Vitorond 200 VD2 Series 320 to 1080 Service Instructions (page 16). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.