Viessmann · Boiler parts

Viessmann Vitotronic 100: parts list

47 replacement parts with OEM part numbers for 11 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Vitotronic 100 boiler control
Pre-wired with Viessmann quick-connect plug-in system
7834 238KW10B1
Control fuse F1, slow blow, for control operation
Wear part. Slow blow fuse for control operation.
091KW10BPackage of 10T 6.3 A / 250 V
Fuse, US style
Wear part. US style fuse.
092KW10BPackage of 56.25 A
Fuse
Wear part.
094KW10BPackage of 50.1 A / 250 V
LON communication module110KW10B1
Relay DPDT115KW10B124 VAC
Interconnector 1/4
Listed under other parts, not illustrated.
120KW10B1
Adjustable high limit
Length or dimension as printed; the printed text is unclear.
031KW10B11=1750 mm
AHL knob033KW10B1
Override switch034KW10B1
Space heating circuit switch035KW10B1
On/Off switch036KW10B1
Outdoor temperature sensor040KW10B15K
Sensor #3, boiler042KW10B110K
Sensor #5, DHW043KW10B110K
Control cable with #41 plug
Shipped with burner or boiler.
065KW10B1
Fuse cover093KW10B1
Motherboard100KW10B1
Circuit board, LED105KW10B1
Cable clip001KW10B1
Adjustable high limit dial004KW10B1
Fixed high limit cover005KW10B1
Flip-down cover007KW10B1
Control housing cover, top010KW10B1
Control housing, front011KW10B1
Control housing, bottom016KW10B1
Thermometer, °C/°F018KW10B1
Switch knockout019KW10B1
Fuse holder023KW10B1
Fuse holder cover024KW10B1
Fixed high limit
Dimension as printed.
030KW10B1190 x 1760 mm
Adjustable high limit
Adjustable high limit on control unit
RAK 51.1/3382 (Etheco) or TR 97.55180.251 (EGO)KW10B1167 °F to 239 °F (75 °C to 115 °C) max.
Fixed high limit
Fixed high limit on control unit
RAK 75.4/3412 (Etheco) or STW 56.10525.400 (EGO)KW10B1230 °F (110 °C) max., fixed
Combustion Air Device Adaptor
Mounts on DIN rail in connection enclosure or boiler junction box
7134 563Vitocrossal 300 VD2/VD2A/CT3/CM21 per boiler120 VAC, max 5 FLA
Common Combustion Air Device Interface
Wall mount, for single blower or damper on multiple boilers
7134 604Multi-boiler systems1 per system120 VAC
Line voltage motherboard
Contains relays and outputs for pumps, control elements and burner; plug-in location for power supply and boiler control section
7165 792All 11 models1
Low-voltage motherboard
Sensor plugs, communication connections, external equipment; plug-in locations for electronics board, LON module, 2-wire BUS module, programming unit, coding card and Optolink board
7820 290All 11 models1
Power supply unit board, 120 VAC
Supplies low voltage to the whole electronics
7823 991All 11 models1120 VAC
Electronics board
Contains microprocessor and software; see replacement steps (codings 8A and 92)
7828 193All 11 models1
Optolink/override switch board
Status and fault indicators, Optolink laptop interface, override switch
7820 165All 11 models1
Programming unit
Inserted in control unit; used to set heating program and set points, and to show temperatures, status and faults
7823 990All 11 models1
Fuse box
Contains fixed high limit, adjustable high limit, fuses, heating system switch and TUV button
7820 175All 11 models1
LON communication module
Accessory; inserted in control unit
7172 173All 11 models1
Terminal resistor (LON)
One on first and one on last control unit
7143 497Vitotronic 050 or Vitotronic 333 reference1
Boiler coding card, Vitocrossal 300 Type CT3
Boiler coding card used with Vitotronic 200
7820 144Vitocrossal 300, Type CT3 (with Vitotronic 200)1
Boiler coding card, Vitorond 200 Type VD2/VD2A
Boiler coding card used with Vitotronic 200
7820 142Vitorond 200, Type VD2/VD2A (with Vitotronic 200)1
Boiler coding card, Vitocrossal 200 Type CM2
Boiler coding card used with Vitotronic 200
7820 145Vitocrossal 200, Type CM2 (with Vitotronic 200)1

Source: Vitotronic 100 KW10B installation manual (pages 1, 3, 33, 69, 109, 110, 111, 112). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.