Viessmann · Boiler · Vitorond 100 series
VR1 40 to 63 parts
88 replacement parts that fit the Viessmann VR1 40 to 63, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Carrying handles Recommended for moving the boiler from the skid to its location; reduces risk of panel damage. | 7189 602 | 1 | |
| Top panel, front | 202 | 1 | |
| Side panel, left | 203 | 1 | |
| Insulation blanket | 204 | 1 | |
| Back panel | 205 | 1 | |
| Insulation blanket, rear | 206 | 1 | |
| Front panel | 207 | 1 | |
| Support bracket | 208 | 1 | |
| Top panel, rear | 209 | 1 | |
| Side panel, right | 210 | 1 | |
| Nameplate Vitorond 100 | 211 | 1 | |
| Cover, edge molding | 212 | 1 | |
| Cover plate | 215 | 1 | |
| Vitotronic retrofit housing | 509 | 1 | |
| Touch-up spray paint, Vitotec silver Other part, not illustrated | 300 | 1 | |
| Touch-up paint stick, Vitotec silver Other part, not illustrated | 301 | 1 | |
| Accessory pack, small parts for insulation jacket Other part, not illustrated | 304 | 1 | |
| Installation fittings for Hydrostat applications Other part, not illustrated | 400 | 1 | |
| Installation fittings for Vitotronic applications Other part, not illustrated | 500 | 1 | |
| Installation, Service and Operating Instructions Other part, not illustrated | 600 | 1 | |
| Warranty sheet, cast iron/residential Other part, not illustrated | 602 | 1 | |
| 5-point sensor well | 001 | 1 | |
| Combustion chamber door refractory | 002 | 1 | |
| Combustion chamber door | 003 | 1 | |
| Hinge bracket | 004 | 1 | |
| Glass-fiber gasket | 005 | 1 | |
| Glass-fiber gasket, 3x116 mm Sold with adhesive | 006 | 1 | 3 x 116 mm |
| Observation port cover | 008 | 1 | |
| Glass-fiber gasket | 010 | 1 | |
| Front section (ASME) Must be sold with a split kit | 018 | 1 | |
| Mid section (ASME) Must be sold with a split kit | 019 | 1 | |
| Rear section (ASME) Must be sold with a split kit | 020 | 1 | |
| Combustion chamber insert | 023 | 1 | |
| Split kit for 1 cast-iron section Required with each replacement cast iron section | 305 | 1 | |
| Sensor well | 404 | 1 | |
| Sediment faucet | 501 | 1 | 3/4 in NPT |
| Pressure relief valve | 502 | 1 | 30 psig |
| Vent pipe adaptor | 503 | 1 | 6 in |
| Junction box Not shown on diagram | 504 | 1 | |
| Accessory pack, burner installation hardware | 505 | 1 | |
| Temperature and pressure gauge | 506 | 1 | |
| Control cable with #41 plug Not shown on diagram | 507 | 1 | |
| Burner cable (#41) Not shown on diagram | 508 | 1 | |
| Return injector nozzle | 510 | 1 | |
| Cleaning brush handle, 800 mm Optional, not standard boiler equipment | 016 | 1 | 800 mm |
| Cleaning brush (no handle) Optional, not standard boiler equipment | 017 | 1 | |
| Hydrostat control, Model 3250-Plus | 0701 | 1 | |
| Electro-well, extended | 0702 | 1 | 3/4 in NPT |
| Hex bushing | 0703 | 1 | 1-1/2 in x 3/4 in |
| Temperature and pressure gauge | 0704 | 1 | |
| Reduction tee | 0705 | 1 | 2 in x 2 in x 1/2 in |
| Nipple | 0706 | 1 | 2 in x 5 in |
| Reduction tee | 0707 | 1 | 2 in x 3/4 in x 2 in |
| 90 degree street elbow | 0708 | 1 | 3/4 in |
| Nipple | 0709 | 1 | 3/4 in x 3-1/2 in |
| Pressure relief valve | 0710 | 1 | 30 psig |
| Reduction tee | 0711 | 1 | 2 in x 2 in x 3/4 in |
| Sediment faucet | 0712 | 1 | |
| Vent pipe adaptor | 0713 | 1 | 6 in |
| Burner cable, 4-wire | 0715 | 1 | 85 in |
| Cable clamp | 0721 | 1 | |
| Accessory pack, burner installation hardware Other part, not illustrated | 0717 | 1 | |
| Remote mounting kit with 48 in sensor cable Other part, not illustrated | 0722 | 1 | 48 in sensor cable |
| Installation, Operation and Service Instructions Other part, not illustrated | 0730 | 1 | |
| Installation and operating instructions, Hydrostat Other part, not illustrated | 0732 | 1 | |
| Warranty sheet, cast iron/residential Other part, not illustrated | 0733 | 1 | |
| Parts list, installation set Other part, not illustrated | 0734 | 1 | |
| Top panel, front Illustrated | 202 | 1 | |
| Side panel, left Illustrated | 203 | 1 | |
| Insulation blanket Illustrated | 204 | 1 | |
| Back panel Illustrated | 205 | 1 | |
| Insulation blanket, rear Illustrated | 206 | 1 | |
| Front panel Illustrated | 207 | 1 | |
| Support bracket Illustrated | 208 | 1 | |
| Top panel, rear Illustrated | 209 | 1 | |
| Side panel, right Illustrated | 210 | 1 | |
| Nameplate "Vitorond 100" Illustrated | 211 | 1 | |
| Cover, edge molding Illustrated | 212 | 1 | |
| Cover plate Illustrated | 215 | 1 | |
| Vitotronic retrofit housing Illustrated | 509 | 1 | |
| Touch-up spray paint, Vitotec silver Not illustrated | 300 | 1 | |
| Touch-up paint stick, Vitotec silver Not illustrated | 301 | 1 | |
| Accessory pack, small parts for insulation jacket Not illustrated | 304 | 1 | |
| Installation fittings for Hydrostat applications Not illustrated | 400 | 1 | |
| Installation fittings for Vitotronic applications Not illustrated | 500 | 1 | |
| Installation, Service and Operating Instructions Not illustrated | 600 | 1 | |
| Warranty Sheet, Cast iron/Residential Not illustrated | 602 | 1 | |
| Rating plate (location of serial no.) Reference letter as shown in parts list | A | 1 |
Same series
The Vitorond 100 parts list shows every part for all 21 models side by side. Other models: 140, 161, 161 to 245, 196, 245, 27, 33, 50, 63, 91, VR1 161 to 245, VR1 22, VR1 22, 91, VR1 27, VR1 27, 105, VR1 33, VR1 33, 140, VR1 40, VR1 50, VR1 63.
Source: Vitorond 100 installation and service manual (pages 11, 48, 52, 53, 54). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.