Viessmann · Boiler · Vitorond 100 series

33 parts

83 replacement parts that fit the Viessmann 33, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Top panel, front
Illustrated
2021
Side panel, left
Illustrated
2031
Insulation blanket
Illustrated
2041
Back panel
Illustrated
2051
Insulation blanket, rear
Illustrated
2061
Front panel
Illustrated
2071
Support bracket
Illustrated
2081
Top panel, rear
Illustrated
2091
Side panel, right
Illustrated
2101
Nameplate "Vitorond 100"
Illustrated
2111
Cover, edge molding
Illustrated
2121
Cover plate
Illustrated
2151
Vitotronic retrofit housing
Illustrated
5091
Touch-up spray paint, Vitotec silver
Not illustrated
3001
Touch-up paint stick, Vitotec silver
Not illustrated
3011
Accessory pack, small parts for insulation jacket
Not illustrated
3041
Installation fittings for Hydrostat applications
Not illustrated
4001
Installation fittings for Vitotronic applications
Not illustrated
5001
Installation, Service and Operating Instructions
Not illustrated
6001
Warranty Sheet, Cast iron/Residential
Not illustrated
6021
Rating plate (location of serial no.)
Reference letter as shown in parts list
A1
Top panel, front2021
Side panel, left2031
Insulation blanket2041
Back panel2051
Insulation blanket, rear2061
Front panel2071
Support bracket2081
Top panel, rear2091
Side panel, right2101
Nameplate "Vitorond 100"2111
Cover, edge molding2121
Cover plate2151
Vitotronic retrofit housing5091
Touch-up spray paint, Vitotec, silver
Not illustrated
3001
Touch-up paint stick, Vitotec silver
Not illustrated
3011
Accessory pack, small parts for insulation jacket
Not illustrated
3041
Installation fittings for Hydrostat applications
Not illustrated
4001
Installation fittings for Vitotronic applications
Not illustrated
5001
Installation, Service and Operating Instructions
Not illustrated
6001
Warranty Sheet, Cast iron/Residential
Not illustrated
6021
Rating plate (location of serial no.)
Not illustrated
A1
5-Point sensor well0011
Combustion chamber door refractory0021
Combustion chamber door0031
Hinge bracket0041
Glass-fiber gasket, 16 x 12 L=2000 mm005116 x 12 mm, 2000 mm length
Glass-fiber gasket, 3 x 116 mm
Sold with adhesive
00613 x 116 mm
Observation port cover0081
Combustion chamber insert0231
Sediment faucet, 3/4" NPT50113/4 in NPT
Pressure relief valve502130 psig
Vent pipe adaptor50315 in
Junction box
Not shown on diagram
5041
Accessory pack, burner installation hardware5051
Temperature and pressure gage5061
Control cable with #41 plug
Not shown on diagram
5071#41 plug
Burner cable (#41)
Not shown on diagram
5081#41
Return injector nozzle5101
Cleaning brush handle, 800 mm, M10
Optional, not standard equipment
0161800 mm, M10
Cleaning brush (no handle)
Optional, not standard equipment
0171
Hydrostat control, 3250-Plus07011
Electro well, extended 3/4 in NPT070213/4 in NPT
Hex bushing, 1-1/4 x 3/4 in070311-1/4 x 3/4 in
Temperature and pressure gage07041
Reduction tee, 1-1/2 x 1-1/2 x 1/2 in070511-1/2 x 1-1/2 x 1/2 in
Nipple, 1-1/2 x 5 in070611-1/2 x 5 in
Reduction tee, 1-1/2 x 3/4 x 1-1/2 in070711-1/2 x 3/4 x 1-1/2 in
90 degree street elbow, 3/4 in070813/4 in
Nipple, 3/4 x 3-1/2 in070913/4 x 3-1/2 in
Pressure relief valve0710130 psig
Reduction tee, 1-1/2 x 1-1/2 x 3/4 in071111-1/2 x 1-1/2 x 3/4 in
Sediment faucet07121
Vent pipe adaptor071315 in
Burner cable, 85 in (4-wire)0715185 in, 4-wire
Cable clamp07211
Accessory pack, burner installation hardware
Not illustrated
07171
Remote mounting kit (with 48 in sensor cable)
Not illustrated
0722148 in sensor cable
Installation, Operation and Service Instructions
Not illustrated
07301
Installation, Operating Instructions, Hydrostat 3250-Plus
Not illustrated
07321
Installation Instructions, Direct Vent
Not illustrated
07331
Warranty Sheet, Cast-Iron, Residential
Not illustrated
07341
Parts List, Installation Set
Not illustrated
07351

Same series

The Vitorond 100 parts list shows every part for all 21 models side by side. Other models: 140, 161, 161 to 245, 196, 245, 27, 50, 63, 91, VR1 161 to 245, VR1 22, VR1 22, 91, VR1 27, VR1 27, 105, VR1 33, VR1 33, 140, VR1 40, VR1 40 to 63, VR1 50, VR1 63.

Source: Vitorond 100 installation and service manual (pages 48, 49, 50). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.