Viessmann · Boiler parts

Viessmann Vitocontrol-S VD2/CT3/CM2: parts list

48 replacement parts with OEM part numbers for 7 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Combustion Air Device Adaptor
DIN rail mounted in the connection enclosure or boiler junction box
7134 563VD2, VD2A, CT3, CM21Blower supply 120 VAC, max 5 FLA
LON cable
Connects control units and Vitocom on the LON network
7143 495All 7 models1
End of line resistor
Standard delivery with Vitocontrol-S; fitted at both ends of LON line
7143 497All 7 models1
LON extension jack
Coupling for LON cable extensions
7143 496All 7 models1
120V valve adaptor
For 120V modulating valve actuators; DIN rail mounted
7134 560All 7 models1120 VAC, max 0.1 FLA
24V valve adaptor
For 24V modulating valve actuators; DIN rail mounted
7134 559All 7 models124 VAC, max 0.15 FLA
Programming unit
Sets heating program, set values, switching times, heating curve, date, time, economy and party mode, and codings
7823 986All 7 models1
Mixing valve motor
Mixing valve circuit extension kit
7133 390All 7 models1120 VAC, 60 Hz, 4 W, 3 Nm, IP 42
Vitotrol 200 remote control with integral room temperature sensor
For mixing valve circuit room temperature feedback. Controls day temperature, heating program and economy/party mode.
7133 378All 7 models1Setting range 10 to 30 C (50 to 96 F), adjustable 3 to 23 C or 17 to 37 C via E1
Vitotrol 300 remote control with integral room temperature sensor
For mixing valve circuit room temperature feedback. Controls normal and reduced temperature, DHW temperature, heating program, holiday program, switching times and economy/party mode.
7134 452All 7 models1Normal set room temp 10 to 30 C (50 to 86 F); reduced set room temp 3 to 37 C (37 to 97 F)
Room temperature sensor
Measures actual room temperature when the Vitotrol unit cannot be mounted in a suitable location. Connect at terminals 9 and 13b.
7133 379All 7 models1Protection IP 30; operation 0 to +40 C (32 to 104 F); storage -20 to +65 C (-4 to +149 F)
Hinges001MW1 series1
Support arm008MW1 series1
Power module (wired)011MW1 series1
Front housing (with Pos. 001)013MW1 series1
Circuit board enclosure014MW1 series1
Flip-down cover015MW1 series1
Rear housing016MW1 series1
Wall console017MW1 series1
Programming unit018MW1 series1
Flip-down cover019MW1 series1
Front cover (heating circuits)020MW1 series1
Flat cable, 14-pole021MW1 series114-pole
Fuse holder cover024MW1 series1
Fuse holder025MW1 series1
Switch, 2-pole (power on/off)038MW1 series12-pole
Sensor #1 for outdoor temperature040MW1 series1
Sensor #5 for DHW production043MW1 series1
LON module047MW1 series1
Circuit board (mixing valve expansion)048MW1 series1
Motherboard (control, low voltage)049MW1 series1
Circuit board (control software)050MW1 series1
Diagnostics module (Optolink)051MW1 series1
Motherboard (control, line voltage)052MW1 series1
Circuit board (120 V power supply)054MW1 series1120 V
Motherboard (mixing valve expansion)055MW1 series1
Sensor (immersion, NI500)067MW1 series1NI500
Sensor #2 for supply068MW1 series1
Harness for programming unit074MW1 series1
Fuse (10 pack)092MW1 series10 pack6.3 A / 250 V
Connecting cable LON (7 m), RJ45093MW1 series17 m, RJ45
LON terminal resistor (2 pieces)094MW1 series2
Accessory pack (plugs)
Not illustrated
060MW1 series1
Installation / Service Instructions Vitotronic 100/333
Not illustrated
080MW1 series1
Operating Instructions, Vitotronic 100/333
Not illustrated
081MW1 series1
Parts List, Vitotronic 333
Not illustrated
082MW1 series1
Accessory pack (low voltage plugs)
Not illustrated
100MW1 series1
Accessory pack (strain reliefs and plugs)
Not illustrated
107MW1 series1

Source: Vitocontrol-S, VD2/CT3/CM2 installation and service instructions (pages 54, 83, 86, 140, 144, 146, 148, 152, 193, 194). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.