Viessmann · Boiler · Vitocontrol-S VD2/CT3/CM2 series
CM2 parts
11 replacement parts that fit the Viessmann CM2, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Combustion Air Device Adaptor DIN rail mounted in the connection enclosure or boiler junction box | 7134 563 | 1 | Blower supply 120 VAC, max 5 FLA |
| LON cable Connects control units and Vitocom on the LON network | 7143 495 | 1 | |
| End of line resistor Standard delivery with Vitocontrol-S; fitted at both ends of LON line | 7143 497 | 1 | |
| LON extension jack Coupling for LON cable extensions | 7143 496 | 1 | |
| 120V valve adaptor For 120V modulating valve actuators; DIN rail mounted | 7134 560 | 1 | 120 VAC, max 0.1 FLA |
| 24V valve adaptor For 24V modulating valve actuators; DIN rail mounted | 7134 559 | 1 | 24 VAC, max 0.15 FLA |
| Programming unit Sets heating program, set values, switching times, heating curve, date, time, economy and party mode, and codings | 7823 986 | 1 | |
| Mixing valve motor Mixing valve circuit extension kit | 7133 390 | 1 | 120 VAC, 60 Hz, 4 W, 3 Nm, IP 42 |
| Vitotrol 200 remote control with integral room temperature sensor For mixing valve circuit room temperature feedback. Controls day temperature, heating program and economy/party mode. | 7133 378 | 1 | Setting range 10 to 30 C (50 to 96 F), adjustable 3 to 23 C or 17 to 37 C via E1 |
| Vitotrol 300 remote control with integral room temperature sensor For mixing valve circuit room temperature feedback. Controls normal and reduced temperature, DHW temperature, heating program, holiday program, switching times and economy/party mode. | 7134 452 | 1 | Normal set room temp 10 to 30 C (50 to 86 F); reduced set room temp 3 to 37 C (37 to 97 F) |
| Room temperature sensor Measures actual room temperature when the Vitotrol unit cannot be mounted in a suitable location. Connect at terminals 9 and 13b. | 7133 379 | 1 | Protection IP 30; operation 0 to +40 C (32 to 104 F); storage -20 to +65 C (-4 to +149 F) |
Same series
The Vitocontrol-S VD2/CT3/CM2 parts list shows every part for all 7 models side by side. Other models: 300-K MW1, CT3, MW1 series, VD2, VD2A, Vitocontrol-S, VD2/CT3/CM2, 300-K MW1.
Source: Vitocontrol-S, VD2/CT3/CM2 installation and service instructions (pages 54, 83, 86, 140, 144, 146, 148, 152). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.