Viessmann · Boiler · Vitocontrol-S VD2/CT3/CM2 series

300-K MW1 parts

10 replacement parts that fit the Viessmann 300-K MW1, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
LON cable
Connects control units and Vitocom on the LON network
7143 4951
End of line resistor
Standard delivery with Vitocontrol-S; fitted at both ends of LON line
7143 4971
LON extension jack
Coupling for LON cable extensions
7143 4961
120V valve adaptor
For 120V modulating valve actuators; DIN rail mounted
7134 5601120 VAC, max 0.1 FLA
24V valve adaptor
For 24V modulating valve actuators; DIN rail mounted
7134 559124 VAC, max 0.15 FLA
Programming unit
Sets heating program, set values, switching times, heating curve, date, time, economy and party mode, and codings
7823 9861
Mixing valve motor
Mixing valve circuit extension kit
7133 3901120 VAC, 60 Hz, 4 W, 3 Nm, IP 42
Vitotrol 200 remote control with integral room temperature sensor
For mixing valve circuit room temperature feedback. Controls day temperature, heating program and economy/party mode.
7133 3781Setting range 10 to 30 C (50 to 96 F), adjustable 3 to 23 C or 17 to 37 C via E1
Vitotrol 300 remote control with integral room temperature sensor
For mixing valve circuit room temperature feedback. Controls normal and reduced temperature, DHW temperature, heating program, holiday program, switching times and economy/party mode.
7134 4521Normal set room temp 10 to 30 C (50 to 86 F); reduced set room temp 3 to 37 C (37 to 97 F)
Room temperature sensor
Measures actual room temperature when the Vitotrol unit cannot be mounted in a suitable location. Connect at terminals 9 and 13b.
7133 3791Protection IP 30; operation 0 to +40 C (32 to 104 F); storage -20 to +65 C (-4 to +149 F)

Same series

The Vitocontrol-S VD2/CT3/CM2 parts list shows every part for all 7 models side by side. Other models: CM2, CT3, MW1 series, VD2, VD2A, Vitocontrol-S, VD2/CT3/CM2, 300-K MW1.

Source: Vitocontrol-S, VD2/CT3/CM2 installation and service instructions (pages 83, 86, 140, 144, 146, 148, 152). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.