Viessmann · Boiler · Vitotronic 100 GC1 series

GC1 Series parts

40 replacement parts that fit the Viessmann GC1 Series, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
120V Valve Adaptor
Boiler return mixing or isolation/modulating valve actuator adaptor; mounts on DIN rail in connection enclosure
7134 5601120 VAC, max 0.1 FLA
24V Valve Adaptor
Boiler return mixing or isolation/modulating valve actuator adaptor; mounts on DIN rail in connection enclosure
7134 559124 VAC, max 0.15 FLA
Combustion Air Device Adaptor
Mounts on DIN rail in connection enclosure; wires BK2 to terminal 16 and BK3 to terminal 17
7134 5631120 VAC blower, max 5 FLA
Common Combustion Air Device Interface (wall mount)
Shares one combustion air device across a multiple boiler system
7134 6041120 VAC
Hinges
Position number from parts illustration; order no. not printed
0011
Optic link
Position number from parts illustration; order no. not printed
0021
Adjustable high limit knob
Position number from parts illustration; order no. not printed
0041
Fixed high limit cover
Position number from parts illustration; order no. not printed
0051
Dial-stop 110°C / 230°F
Position number from parts illustration; order no. not printed
0061110°C / 230°F
Support arm
Position number from parts illustration; order no. not printed
0081
Safety module (wired)
Position number from parts illustration; order no. not printed
0111
Front housing (with Pos. 001)
Position number from parts illustration; order no. not printed
0131
Circuit board enclosure
Position number from parts illustration; order no. not printed
0141
Flip-down cover
Position number from parts illustration; order no. not printed
0151
Rear housing
Position number from parts illustration; order no. not printed
0161
Programming unit
Position number from parts illustration; order no. not printed
0181
Fuse holder cover
Position number from parts illustration; order no. not printed
0241
Fuse holder
Position number from parts illustration; order no. not printed
0251
Fixed high limit
Position number from parts illustration; order no. not printed
0301
Adjustable high limit
Position number from parts illustration; order no. not printed
0311
Switch, 1-pole (FHL test)
Position number from parts illustration; order no. not printed
0371
Switch, 2-pole (power on/off)
Position number from parts illustration; order no. not printed
0381
Sensor #3 for boiler
Position number from parts illustration; order no. not printed
0421
Sensor #5 for domestic hot water production
Position number from parts illustration; order no. not printed
0431
Motherboard (control, low voltage)
Position number from parts illustration; order no. not printed
0491
Circuit board (control software)
Position number from parts illustration; order no. not printed
0501
Diagnostics module (Optolink)
Position number from parts illustration; order no. not printed
0511
Motherboard (control, line voltage)
Position number from parts illustration; order no. not printed
0521120 VAC line voltage
Circuit board (120V power supply)
Position number from parts illustration; order no. not printed
0541120 V
Communication module, 2-wire BUS
Position number from parts illustration; order no. not printed
0551
LON module
Position number from parts illustration; order no. not printed
0561
Accessory pack (plugs)
Other part, not illustrated
0601
Burner cable Nr. 41/90 l=3470
Position number from parts illustration; order no. not printed
0651l=3470
Sensor (immersion, NI500)
Position number from parts illustration; order no. not printed
0671NI500
Sensor #2 for supply
Position number from parts illustration; order no. not printed
0681
Harness for programming unit
Position number from parts illustration; order no. not printed
0741
Fuse 6.3A / 250V (10 pack)
Position number from parts illustration; order no. not printed
09210 pack6.3A / 250V
Installation / Service Instructions Vitotronic 100, GC1
Other part, not illustrated
0801
Operating Instructions Vitotronic 100, GC1
Other part, not illustrated
0811
Parts List Vitotronic 100, GC1
Other part, not illustrated
0821

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 130 (pages 37, 40, 42, 130). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.