Navien heat pump error codes
50 codes (37 faults, 13 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| d0 | Oil return cycle | Normal status |
| F4 | T4 outdoor ambient sensor fault | Medium |
| F5 | T5 compressor discharge sensor fault | Medium |
| F6 | T3 condenser coil sensor fault | Medium |
| F7 | T7 sensor fault | Medium |
| F8 | T7 sensor: condensate risk on the cooling plate | Medium |
| F9 | Line voltage too low or too high | High |
| H0 | Communication fault between chips on the outdoor PCB | High |
| H1 | Lockout: outdoor coil too hot (P5 repeated) | High |
| H2 | Lockout: high pressure switch (P1 repeated) | High |
| H3 | Lockout: high pressure in heating (PD repeated) | High |
| H4 | Lockout: drive module overheating (P8 repeated) | High |
| H5 | Lockout: low pressure (P2 repeated) | High |
| H6 | Lockout: high discharge temperature (P4 repeated) | High |
| H7 | Lockout: low discharge superheat (PC repeated) | High |
| H8 | Lockout: T3 probe off the pipe (FE repeated) | High |
| L0 | DC bus voltage too low | High |
| L1 | DC bus voltage too high | High |
| P1 | High pressure switch opened | High |
| P2 | Low pressure protection | High |
| P3 | Compressor drive overcurrent | High |
| P4 | Discharge temperature too high | High |
| P5 | Outdoor coil too hot in cooling | High |
| P6 | Compressor drive (IPM) module protection | Critical |
| P7 | Indoor coil freeze protection (T2) | High |
| P8 | Drive module (IPM) overheating | High |
| P9 | Outdoor fan motor fault | High |
| ATL | Outdoor temperature outside operating range | Medium |
| FA | Outdoor board memory (EEPROM) fault | High |
| FB | Drive chip memory (EEPROM) fault | High |
| FC | Drive module temperature sensor fault | High |
| FD | Pressure sensor not detected | High |
| FE | T3 or T5 probe out of position | Medium |
| FF | High pressure switch reads open all the time | High |
| HC | Lockout: discharge probe off the pipe (FE repeated) | High |
| HE | Repeated condensate-risk faults (F8) | Medium |
| IoT LED boot | IoT module boot mode | Normal status |
| IoT LED pairing | IoT module pairing / operation | Normal status |
| IoT Wi-Fi LED color | IoT Wi-Fi signal color | Normal status |
| LA | Compressor speed held back by voltage | Normal status |
| LB | Compressor speed held back by high pressure | Normal status |
| LC | Compressor speed held back by condenser temperature | Normal status |
| LD | Compressor speed held back by discharge temperature | Normal status |
| LE | Compressor speed held back by drive module temperature | Normal status |
| LF | Compressor speed held back by current | Normal status |
| PC | Low discharge superheat (liquid floodback risk) | High |
| PD | High pressure too high in heating | High |
| PRH | Crankcase heater warm-up, no start yet | Normal status |
| dC | Forced cooling | Normal status |
| df | Defrost | Normal status |
Models covered
NAC-10SMNAZ17V36NAZ17V60
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.