Navien · Heat pump
IoT Wi-Fi LED color IoT Wi-Fi signal color
What the display is showing
Wi-Fi LED in NaviLink Operation Mode: red = disconnected, blue = -55 dBm or stronger, green = -56 to -65, yellow = -66 to -75, purple = -76 or weaker.
Applies to: NAC-10SM IoT module on NAZ heat pump and NAE air conditioner
Models that show this code
2 models in Navien NAZ, Navien NAE
Other codes on the same units
- HC Lockout: discharge probe off the pipe (FE repeated)
- HE Repeated condensate-risk faults (F8)
- IoT LED boot IoT module boot mode
- IoT LED pairing IoT module pairing / operation
- LA Compressor speed held back by voltage
- LB Compressor speed held back by high pressure
- LC Compressor speed held back by condenser temperature
- LD Compressor speed held back by discharge temperature
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NAC-10SM IoT Module Operation & Installation Manual, Modes, p.5-7 and 14-16. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.