HTP boiler error codes

32 codes (20 faults, 12 normal display and menu codes).

CodeMeaningSeverity / type
E03System sensor failure (cascade)Medium
E07Flue temperature highHigh
E19Line voltage frequency out of rangeMedium
F00Water high temperature (ECO)Critical
F01Flue temperature switch / low waterCritical
F02Supply sensor failureHigh
F03Return sensor failureHigh
F04Flue sensor failureHigh
F05Supply temperature highCritical
F06Return temperature highCritical
F09No flame on ignitionCritical
F10Flame lossCritical
F11False flame signalCritical
F13Fan speed errorHigh
F20Condensate fullHigh
F31Program errorHigh
CASCADE MASTER READYCascade master readyNormal status
CASCADE NO FOLLOWERCascade - no followerNormal status
CASCADE NO SENSORCascade - no system sensorNormal status
DHWTemperature blocking - DHW demandNormal status
FLLow water flowMenu / mode display
FLUHigh flue pressureHigh
FOUOutdoor sensor faultLow
GAS VALVE ON / RUNIgnition then run statusNormal status
LOCKOUTLockout (display message)Normal status
LOU24 volt supply lowMedium
MAINTENANCE REQUIREDService reminderNormal status
PPControl programmedNormal status
PROLow water pressureMedium
SERVICE PUMP CH / DH / SHPump service modeMenu / mode display
SERVICE RUNTest mode runningMenu / mode display
TTTemperature blocking - thermostat (TT) demandNormal status

Models covered

EL-110 LPEL-110 NEL-150 LPEL-150 NEL-220 LPEL-220 NEL-299 LPEL-299 NEL-399 LPEL-399 NEL-80 LPEL-80 N

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.