Navien combi boiler error codes

110 codes (62 faults, 48 normal display and menu codes), plus 4 settings tables.

CodeMeaningSeverity / type
E001Heat exchanger overheatHigh
E002Low pressure on the heating sideMedium
E003Ignition failureHigh
E004False flame detectedHigh
E005Heating supply sensor openMedium
E006Heating supply sensor shortedMedium
E007DHW outlet sensor openMedium
E008DHW outlet sensor shortedMedium
E009Fan motor faultHigh
E010Air pressure faultHigh
E011High pressure on the heating sideHigh
E012Flame lossHigh
E013Pump faultHigh
E015PCB faultHigh
E016Heat exchanger overheat (overheating of heat exchanger)High
E018Heating return sensor openMedium
E019Heating return sensor shortedMedium
E021DHW cold inlet sensor openMedium
E022DHW cold inlet sensor shortedMedium
E027Air pressure sensor faultMedium
E028Leak on the heating sideHigh
E030Exhaust overheat (abnormal exhaust temperature)High
E031Burner overheatHigh
E035Gas pressure sensor faultHigh
E036Communication failureMedium
E037Water leak inside the unitHigh
E039Flow sensor faultMedium
E040Outdoor sensor shortedLow
E046Heat exchanger thermistor / overheat sensor faultMedium
E047Exhaust thermistor faultMedium
E048Low LP gas pressure (propane models)High
E060Dual venturi faultMedium
E109Fan motor faultHigh
E110Exhaust blockage / abnormal air pressure (APS)High
E205Heating supply temperature sensor faultMedium
E218Heating return temperature sensor faultMedium
E278External (system) supply sensor not detectedMedium
E279External (system) return sensor not detectedMedium
E302Low water pressure (internal LWCO)High
E351Auto feeder (make-up water) valve faultHigh
E352High water pressureHigh
E353Water pressure sensor faultMedium
E407DHW outlet temperature sensor faultMedium
E421DHW cold water inlet sensor faultMedium
E434Water adjustment (flow control) valve faultMedium
E439No DHW flow detected / flow sensor faultMedium
E441DHW outlet 2 sensor faultMedium
E445Mixing (bypass) valve faultMedium
E515PCB faultHigh
E517DIP switch setting faultMedium
E594EEPROM faultMedium
E615Memory fault (input and memory)Medium
E736Cascade communication faultMedium
E740Outdoor sensor not detectedLow
E761Pump aquastat (pre-heat aquastat) not detectedLow
E762Vent pipe not fully inserted (VID)Critical
E773Improper gas type detectedCritical
E777Low water cutoff (LWCO) activatedHigh
E782Front panel communication faultMedium
E784Zone controller communication faultLow
E786Improper front panelMedium
E788Incorrect gas type settingCritical
Outlet2 TempStatus Information item 10 - Outlet2 TempMenu / mode display
AHU SH Set TempStatus Information item 5 - AHU SH Set TempMenu / mode display
AHU connection iconAir handler connectionNormal status
Anti-freeze iconAnti-freeze mode activeNormal status
Approx. Boiler FlowStatus Information item 14 - Approx. Boiler FlowMenu / mode display
Auto air purge iconAuto air purge runningNormal status
Boost Interval TimeStatus Information item 27 - Boost Interval TimeMenu / mode display
Cascade/Main iconCascade main unitNormal status
Combustion iconBurner combustingNormal status
DHW FlowStatus Information item 15 - DHW FlowMenu / mode display
DHW Set TempStatus Information item 4 - DHW Set TempMenu / mode display
DHW demand iconDHW demand presentNormal status
DHW operation iconDHW preheat feature activeNormal status
DHW set temperatureDHW set temperature displayNormal status
Exhaust TempStatus Information item 24 - Exhaust TempMenu / mode display
Fan Current APSStatus Information item 21 - Fan Current APSMenu / mode display
Fan Current RPMStatus Information item 19 - Fan Current RPMMenu / mode display
Fan Target APSStatus Information item 20 - Fan Target APSMenu / mode display
Fan Target RPMStatus Information item 18 - Fan Target RPMMenu / mode display
Flame ValueStatus Information item 17 - Flame ValueMenu / mode display
Flow Control ValveStatus Information item 22 - Flow Control ValveMenu / mode display
GasStatus Information item 31 - GasMenu / mode display
Heat CapacityStatus Information item 2 - Heat CapacityMenu / mode display
High AltitudeStatus Information item 28 - High AltitudeMenu / mode display
Inlet TempStatus Information item 12 - Inlet TempMenu / mode display
Main F/W VerStatus Information item 32 - Main F/W VerMenu / mode display
Mixing ValveStatus Information item 23 - Mixing ValveMenu / mode display
ModelStatus Information item 30 - ModelMenu / mode display
Operation StateStatus Information item 1 - Operation StateMenu / mode display
Outdoor ResetStatus Information item 25 - Outdoor ResetMenu / mode display
Outdoor Reset CurveStatus Information item 26 - Outdoor Reset CurveMenu / mode display
Outdoor TempStatus Information item 13 - Outdoor TempMenu / mode display
Outdoor reset iconOutdoor reset enabledNormal status
Outdoor temperatureOutdoor temperature displayNormal status
Outlet TempStatus Information item 11 - Outlet TempMenu / mode display
Panel F/W VerStatus Information item 33 - Panel F/W VerMenu / mode display
Return TempStatus Information item 7 - Return TempMenu / mode display
SH Set TempStatus Information item 3 - SH Set TempMenu / mode display
Space heating demand iconSpace heating demandNormal status
Space heating set temperatureSpace heating set temperature displayNormal status
Status InformationStatus Information menuMenu / mode display
Supply TempStatus Information item 6 - Supply TempMenu / mode display
Sys Return TempStatus Information item 9 - Sys Return TempMenu / mode display
Sys Supply TempStatus Information item 8 - Sys Supply TempMenu / mode display
System check iconSystem check or error neededNormal status
System pressureSystem pressure displayNormal status
Water PressureStatus Information item 16 - Water PressureMenu / mode display
Well PumpStatus Information item 29 - Well PumpMenu / mode display

Settings and specs

Minimum installation clearances (indoor)

Clearances · Navien NCB-H

SideMinimum
Top9 in (229 mm)
Back0.5 in (13 mm)
Front4 in (100 mm)
Sides3 in (76 mm)
Bottom12 in (300 mm)
  • Indoor wall-hung only; ambient must stay above 32°F (0°C).
  • Do not install on carpet; leave room for service.

Source: Navien NCB-H Installation & Operation Manual, 2.1 Adequate Installation Clearances, p.15

Water quality limits (DHW and system fill)

Specifications · Navien NCB-H

ContaminantMax allowed
Total hardness200 mg/l (12 grains/gallon)
Aluminum0.05 to 0.2 mg/l
Chloride250 mg/l
Copper1.0 mg/l
Iron0.3 mg/l
Manganese0.05 mg/l
pH6.5 to 8.5
Sulfate250 mg/l (DHW table); 205 mg/l (fill table)
Total dissolved solids500 mg/l
Zinc5 mg/l
Chlorine (fill water)4 mg/l
  • Scale damage from poor water is not covered by warranty.
  • Manual shows sulfate 250 mg/l on p.23 and 205 mg/l on p.29 - check local guidance.

Source: Navien NCB-H Installation & Operation Manual, 3.2 About the DHW Quality p.23 and 3.5 Testing the Water System p.29

Minimum installation clearances (indoor)

Clearances · Navien NFC-H

SideMinimum
Top9 in (229 mm)
Back0.5 in (13 mm)
Front4 in (100 mm)
Sides3 in (76 mm)
Bottom12 in (300 mm)
  • Indoor wall-hung only; ambient must stay above 32°F (0°C).
  • Do not install on carpet; leave room for service.

Source: Navien NFC-H Installation Manual, 2.2 Adequate Installation Clearances, p.18

Water quality limits (DHW and system fill)

Specifications · Navien NFC-H

ContaminantMax allowed
Total hardness200 mg/l (12 grains/gallon)
Aluminum0.05 to 0.2 mg/l
Chloride250 mg/l
Copper1.0 mg/l
Iron0.3 mg/l
Manganese0.05 mg/l
pH6.5 to 8.5
Sulfate250 mg/l (DHW table); 205 mg/l (fill table)
Total dissolved solids500 mg/l
Zinc5 mg/l
Chlorine (fill water)4 mg/l
  • Manual shows sulfate 250 mg/l on p.26 and 205 mg/l on p.33.

Source: Navien NFC-H Installation Manual, 3.2 DHW water quality p.26 and 3.4 fill water p.33

Models covered

CH-180 ASMECH-210 ASMECH-240 ASMENCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150HNFC-250/175HNFC-250/200H

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.