Navien · Combi boiler

E010 Air pressure fault

High severity Navien CH ASME

What the control is telling you

Abnormal air pressure in the combustion system. A strong wind gust down the flue can also trip it.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Likely causes

  • Blocked exhaust pipe
  • Dirty intake air filter
  • Strong back-draft from wind

Test and repair steps

  1. Reset first switch the remote controller OFF then ON, or unplug the unit and plug it back in. If the code comes back, keep going.
  2. Check the exhaust pipe and termination for blockage.
  3. Turn off power before opening the cabinet.
  4. Clean the intake air filter. The manual says a blocked filter shows code 10. Clean it every 3 to 4 months.

Settings for these units

Models that show this code

3 models in Navien CH ASME

CH-180 ASMECH-210 ASMECH-240 ASME

Other codes on the same units

  • E005 Heating supply sensor open
  • E006 Heating supply sensor shorted
  • E007 DHW outlet sensor open
  • E008 DHW outlet sensor shorted
  • E009 Fan motor fault
  • E011 High pressure on the heating side
  • E013 Pump fault
  • E015 PCB fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Error Code Guide, p.42. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.