Navien · Combi boiler

E019 Heating return sensor shorted

Medium severity Navien CH ASME

What the control is telling you

The space heating return temperature sensor reads shorted.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Likely causes

  • Shorted sensor or wiring

Test and repair steps

  1. Reset first switch the remote controller OFF then ON, or unplug the unit and plug it back in. If the code comes back, keep going.
  2. Turn off power before opening the cabinet.
  3. Check the return sensor and its wiring.
  4. Replace the sensor if it is shorted.

Settings for these units

Models that show this code

3 models in Navien CH ASME

CH-180 ASMECH-210 ASMECH-240 ASME

Other codes on the same units

  • E011 High pressure on the heating side
  • E013 Pump fault
  • E015 PCB fault
  • E018 Heating return sensor open
  • E021 DHW cold inlet sensor open
  • E022 DHW cold inlet sensor shorted
  • E027 Air pressure sensor fault
  • E028 Leak on the heating side

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Error Code Guide, p.43. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.