E027 Air pressure sensor fault
What the control is telling you
The air pressure sensor is not reading right.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
Likely causes
- Blocked exhaust or intake pipe
- Dirty intake air filter
Test and repair steps
- Reset first switch the remote controller OFF then ON, or unplug the unit and plug it back in. If the code comes back, keep going.
- Check the exhaust and intake pipes for blockage.
- Turn off power before opening the cabinet.
- Clean the intake air filter.
Settings for these units
- Minimum installation clearances (indoor) · Navien NCB-H
- Water quality limits (DHW and system fill) · Navien NCB-H
- Minimum installation clearances (indoor) · Navien NFC-H
- Water quality limits (DHW and system fill) · Navien NFC-H
Models that show this code
3 models in Navien CH ASME
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Error Code Guide, p.43. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.