Navien · Combi boiler
Operation State Status Information item 1 - Operation State
What the display is showing
Current operation state of the boiler. Read-only item 1 in the Status Information menu.
Applies to: NCB-190/060H to NCB-250/150H
What to do
- Menu > 1. Status Information > scroll to the item.
Settings for these units
Minimum installation clearances (indoor) · Navien NCB-H
| Side | Minimum |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
Indoor wall-hung only; ambient must stay above 32°F (0°C).
Do not install on carpet; leave room for service.
Water quality limits (DHW and system fill) · Navien NCB-H
| Contaminant | Max allowed |
|---|---|
| Total hardness | 200 mg/l (12 grains/gallon) |
| Aluminum | 0.05 to 0.2 mg/l |
| Chloride | 250 mg/l |
| Copper | 1.0 mg/l |
| Iron | 0.3 mg/l |
| Manganese | 0.05 mg/l |
| pH | 6.5 to 8.5 |
| Sulfate | 250 mg/l (DHW table); 205 mg/l (fill table) |
| Total dissolved solids | 500 mg/l |
| Zinc | 5 mg/l |
| Chlorine (fill water) | 4 mg/l |
Scale damage from poor water is not covered by warranty.
Manual shows sulfate 250 mg/l on p.23 and 205 mg/l on p.29 - check local guidance.
Models that show this code
5 models in Navien NCB-H
Other codes on the same units
- Inlet Temp Status Information item 12 - Inlet Temp
- Main F/W Ver Status Information item 32 - Main F/W Ver
- Mixing Valve Status Information item 23 - Mixing Valve
- Model Status Information item 30 - Model
- Outdoor Reset Status Information item 25 - Outdoor Reset
- Outdoor Reset Curve Status Information item 26 - Outdoor Reset Curve
- Outdoor Temp Status Information item 13 - Outdoor Temp
- Outdoor reset icon Outdoor reset enabled
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NCB-H User's Information Manual (V1.0 Apr 2024), 3.3 Accessing Basic Menu Items, p.12-13. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.