E761 Pump aquastat (pre-heat aquastat) not detected

Low severity Navien NCB-HNavien NFC-H

What the control is telling you

Recirculation is set to Aquastat mode but the aquastat input is not detected. NFC-H manual lists the reset type as: Alarm.

Applies to: Navien fire-tube combi boilers, NFC-H series (NFC-250/200H, NFC-250/175H) and NCB-H combi boilers (NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H)

Likely causes

  • Aquastat not wired (CNC6 terminal)
  • Aquastat mode selected without an aquastat

Test and repair steps

  1. Check the pre-heat aquastat wiring at the CNC6 terminal (the manual's listed remedy).
  2. If no aquastat is used, select another recirculation option (Always On, Intelligent, Weekly, HotButton).

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NCB-H Installation & Operation Manual, 11.7 Understanding Error Codes, p.129-130; Navien NFC-H Installation Manual, 11.7 Understanding Error Codes, p.127-128. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.