Bosch heat pump error codes
55 codes (34 faults, 21 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| b2 | Indoor T2 sensor fault | Medium |
| b3 | Indoor refrigerant sensor hardware fault | Medium |
| b4 | Indoor refrigerant sensor communication fault | Medium |
| b5 | Indoor to outdoor communication fault | High |
| b7 | R-454B refrigerant leak protection | Critical |
| b8 | Refrigerant sensor past service life | Low |
| C3 | T3 coil sensor not reading correctly in cooling | Medium |
| E7 | T5 discharge sensor not reading correctly | Medium |
| E41 | T3 temperature sensor fault | Medium |
| E42 | T3L temperature sensor fault | Medium |
| E43 | T4 temperature sensor fault | Medium |
| E44 | T5 temperature sensor fault | Medium |
| E45 | Th temperature sensor fault | Medium |
| E51 | Input voltage out of range | High |
| E52 | DC bus voltage out of range | High |
| E81 | EEV coil fault | Medium |
| F1 | High pressure switch protection | High |
| F2 | System lockout (5 low-pressure trips in 100 minutes) | High |
| F4 | Pressure transducer fault | Medium |
| F41 | High pressure sensor fault | Medium |
| F42 | Low pressure sensor fault | Medium |
| H01 | Drive chip communication fault | High |
| LED1 green | Green LED1 on - main board powered | Normal status |
| o37 | Low refrigerant in heating | High |
| P0 | Control board / compressor IPM overheating | High |
| P1 | High pressure protection | High |
| P4 | High compressor discharge temperature | High |
| P5 | Condenser coil temperature protection (cooling) | High |
| P11 | High pressure protection (transducer) | High |
| P21 | Low pressure protection | High |
| P31 | Input over-current protection | High |
| P32 | Compressor over-current protection | High |
| A | Oil return in progress | Normal status |
| AtL | Ambient temperature limited | Low |
| Check button | Point check - read system values on the board display | Menu / mode display |
| EA | Control and drive program mismatch | Medium |
| Force button | Force button - forced cooling/heating (charge mode) | Menu / mode display |
| Force button 6 s | Force button held 6 seconds - manual defrost test | Menu / mode display |
| Force mode display | Force (charge) mode running | Normal status |
| Gateway Bluetooth LED 1 blink | Gateway Bluetooth LED 1 blink - pairing mode | Normal status |
| Gateway Bluetooth LED 2 blinks | Gateway Bluetooth LED 2 blinks - advertising mode | Normal status |
| Gateway Bluetooth LED solid | Gateway Bluetooth LED (blue) steady - connected | Normal status |
| Gateway Connect button | Gateway Connect (Bluetooth) button | Menu / mode display |
| Gateway Factory button | Gateway Factory (diagnostic) button | Menu / mode display |
| Gateway Reset button | Gateway Reset button | Menu / mode display |
| Gateway cellular LED blinking | Gateway cellular LED (amber) blinking - weak signal | Normal status |
| Gateway cellular LED solid | Gateway cellular LED (amber) steady - good signal | Normal status |
| Gateway fault LED off | Gateway fault LED (red) off - no fault | Normal status |
| Gateway power LED 2 blinks | Gateway power LED (green) 2 blinks - booting | Normal status |
| Gateway power LED solid | Gateway power LED (green) steady - powered on | Normal status |
| PH | Low discharge superheat protection | High |
| Protection letter + Hz | Limited operation - protection letter before the frequency | Normal status |
| Running readout | Running - compressor frequency shown | Normal status |
| Standby readout | Standby - outdoor ambient temperature shown | Normal status |
| dF | Defrost in progress | Normal status |
Models covered
BOVA-36HDN1-M20GBOVA-60HDN1-M20GBOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.