Bosch heat pump error codes

55 codes (34 faults, 21 normal display and menu codes).

CodeMeaningSeverity / type
b2Indoor T2 sensor faultMedium
b3Indoor refrigerant sensor hardware faultMedium
b4Indoor refrigerant sensor communication faultMedium
b5Indoor to outdoor communication faultHigh
b7R-454B refrigerant leak protectionCritical
b8Refrigerant sensor past service lifeLow
C3T3 coil sensor not reading correctly in coolingMedium
E7T5 discharge sensor not reading correctlyMedium
E41T3 temperature sensor faultMedium
E42T3L temperature sensor faultMedium
E43T4 temperature sensor faultMedium
E44T5 temperature sensor faultMedium
E45Th temperature sensor faultMedium
E51Input voltage out of rangeHigh
E52DC bus voltage out of rangeHigh
E81EEV coil faultMedium
F1High pressure switch protectionHigh
F2System lockout (5 low-pressure trips in 100 minutes)High
F4Pressure transducer faultMedium
F41High pressure sensor faultMedium
F42Low pressure sensor faultMedium
H01Drive chip communication faultHigh
LED1 greenGreen LED1 on - main board poweredNormal status
o37Low refrigerant in heatingHigh
P0Control board / compressor IPM overheatingHigh
P1High pressure protectionHigh
P4High compressor discharge temperatureHigh
P5Condenser coil temperature protection (cooling)High
P11High pressure protection (transducer)High
P21Low pressure protectionHigh
P31Input over-current protectionHigh
P32Compressor over-current protectionHigh
AOil return in progressNormal status
AtLAmbient temperature limitedLow
Check buttonPoint check - read system values on the board displayMenu / mode display
EAControl and drive program mismatchMedium
Force buttonForce button - forced cooling/heating (charge mode)Menu / mode display
Force button 6 sForce button held 6 seconds - manual defrost testMenu / mode display
Force mode displayForce (charge) mode runningNormal status
Gateway Bluetooth LED 1 blinkGateway Bluetooth LED 1 blink - pairing modeNormal status
Gateway Bluetooth LED 2 blinksGateway Bluetooth LED 2 blinks - advertising modeNormal status
Gateway Bluetooth LED solidGateway Bluetooth LED (blue) steady - connectedNormal status
Gateway Connect buttonGateway Connect (Bluetooth) buttonMenu / mode display
Gateway Factory buttonGateway Factory (diagnostic) buttonMenu / mode display
Gateway Reset buttonGateway Reset buttonMenu / mode display
Gateway cellular LED blinkingGateway cellular LED (amber) blinking - weak signalNormal status
Gateway cellular LED solidGateway cellular LED (amber) steady - good signalNormal status
Gateway fault LED offGateway fault LED (red) off - no faultNormal status
Gateway power LED 2 blinksGateway power LED (green) 2 blinks - bootingNormal status
Gateway power LED solidGateway power LED (green) steady - powered onNormal status
PHLow discharge superheat protectionHigh
Protection letter + HzLimited operation - protection letter before the frequencyNormal status
Running readoutRunning - compressor frequency shownNormal status
Standby readoutStandby - outdoor ambient temperature shownNormal status
dFDefrost in progressNormal status

Models covered

BOVA-36HDN1-M20GBOVA-60HDN1-M20GBOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.