Bosch · Heat pump
AtL Ambient temperature limited
What the control is telling you
Operation is restricted because the outdoor temperature is outside the operating range.
Applies to: Bosch IDS Light BOVA15-24/36/60 and IDS Premium Connected BOVA36-20/60-20 R-454B heat pump outdoor units
Likely causes
- Ambient outside 15-125 F in cooling or -4 to 86 F in heating
- Thermostat O/B setting wrong
- T4 sensor wiring or reading wrong
Test and repair steps
- Wait for the temperature to come back into range.
- Check the thermostat O/B setting for heating.
- Check the T4 resistance against the sensor table; reseat or replace T4 and restart.
- Check wiring against the diagram.
Models that show this code
5 models in Bosch IDS Light, Bosch IDS Premium Connected
Other codes on the same units
- P11 High pressure protection (transducer)
- P21 Low pressure protection
- P31 Input over-current protection
- P32 Compressor over-current protection
- Check button Point check - read system values on the board display
- EA Control and drive program mismatch
- Force button Force button - forced cooling/heating (charge mode)
- Force button 6 s Force button held 6 seconds - manual defrost test
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch IDS Light installation BTC 762003308 D (02.2025), Fault Code Table 23 and 17.12 Error Code Troubleshooting, p.42-59; Bosch IDS Premium Connected installation BTC 762003301 D (02.2025), Fault Code Table 22 and 18.12 Error Code Troubleshooting. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.