Bosch · Heat pump

Check button Point check - read system values on the board display

Menu / mode display Bosch IDS LightBosch IDS Premium Connected

What the display is showing

Pressing the CHECK button on the outdoor control board steps through a list of system values. Each press first shows the point number and, after 1 second, its value. After 20 seconds on one point the display goes back to the normal reading. Example points: 0 unit capacity (H5 = 5-ton heat pump), 1 mode (value 0 = standby, 2 = cooling, 3 = heating), 2 set compressor speed in Hz, 3 last fault code, then coil, ambient, discharge, pressure, superheat, EEV opening, fan, current, voltage, power, run time and software version points. The exact list differs a little between Premium Connected and Light.

Applies to: BOVA IDS Premium Connected (36-60) and IDS Light (BOVA15) heat pumps

What to do

  1. Press the CHECK button (SW2) on the control board
  2. The point number shows, then its value after 1 second
  3. Press CHECK again for the next point
  4. Do nothing for 20 seconds to return to the normal display

Models that show this code

5 models in Bosch IDS Light, Bosch IDS Premium Connected

BOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20

Other codes on the same units

  • P21 Low pressure protection
  • P31 Input over-current protection
  • P32 Compressor over-current protection
  • AtL Ambient temperature limited
  • EA Control and drive program mismatch
  • Force button Force button - forced cooling/heating (charge mode)
  • Force button 6 s Force button held 6 seconds - manual defrost test
  • Gateway Bluetooth LED 1 blink Gateway Bluetooth LED 1 blink - pairing mode

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Bosch IDS Premium Connected BTC 762003301 D (02.2025), 18.9 System Protection Status Codes p.49 and 18.10 Parameter Point Check Table p.50; IDS Light BTC 762003308 D (01.2025), 17.9 p.43 and 17.10 p.44. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.