Bosch · Heat pump
P32 Compressor over-current protection
What the control is telling you
The compressor drew too much current.
Applies to: Bosch IDS Light BOVA15-24/36/60 and IDS Premium Connected BOVA36-20/60-20 R-454B heat pump outdoor units
Likely causes
- Closed valves
- Blocked coils or fan trouble
- Shorted compressor
- Board fault
Test and repair steps
- Warning: Switch off power and wait 3 minutes before measuring resistance or touching boards.
- Open valves; fix wiring.
- Clear coil blockages and check the fan.
- Check compressor windings.
- Replace the board or compressor as indicated.
Models that show this code
5 models in Bosch IDS Light, Bosch IDS Premium Connected
Other codes on the same units
- P4 High compressor discharge temperature
- P5 Condenser coil temperature protection (cooling)
- P11 High pressure protection (transducer)
- P21 Low pressure protection
- P31 Input over-current protection
- AtL Ambient temperature limited
- Check button Point check - read system values on the board display
- EA Control and drive program mismatch
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch IDS Light installation BTC 762003308 D (02.2025), Fault Code Table 23 and 17.12 Error Code Troubleshooting, p.42-59; Bosch IDS Premium Connected installation BTC 762003301 D (02.2025), Fault Code Table 22 and 18.12 Error Code Troubleshooting. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.