Bosch · Heat pump

P11 High pressure protection (transducer)

High severity Bosch IDS LightBosch IDS Premium Connected

What the control is telling you

Pressure-transducer reading shows high head pressure.

Applies to: Bosch IDS Light BOVA15-24/36/60 and IDS Premium Connected BOVA36-20/60-20 R-454B heat pump outdoor units

Likely causes

  • High ambient
  • Restricted refrigerant side
  • Poor heat exchange or failed fan
  • Undercharge or failed sensor

Test and repair steps

  1. Check the ambient temperature.
  2. Open valves and fix restrictions.
  3. Check the fan and coil airflow.
  4. Check charge and replace a failed sensor.

Models that show this code

5 models in Bosch IDS Light, Bosch IDS Premium Connected

BOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20

Other codes on the same units

  • o37 Low refrigerant in heating
  • P0 Control board / compressor IPM overheating
  • P1 High pressure protection
  • P4 High compressor discharge temperature
  • P5 Condenser coil temperature protection (cooling)
  • P21 Low pressure protection
  • P31 Input over-current protection
  • P32 Compressor over-current protection

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Bosch IDS Light installation BTC 762003308 D (02.2025), Fault Code Table 23 and 17.12 Error Code Troubleshooting, p.42-59; Bosch IDS Premium Connected installation BTC 762003301 D (02.2025), Fault Code Table 22 and 18.12 Error Code Troubleshooting. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.