Bosch · Heat pump
b3 Indoor refrigerant sensor hardware fault
What the control is telling you
The R-454B (A2L) leak sensor in the indoor unit has failed.
Applies to: Bosch IDS Light BOVA15-24/36/60 and IDS Premium Connected BOVA36-20/60-20 R-454B heat pump outdoor units
Likely causes
- Failed refrigerant sensor
- Ambient above 140 F at the sensor
Test and repair steps
- If the air around the sensor is above 140 F, no service is needed once it cools.
- Fit a new refrigerant sensor, then restore power.
Models that show this code
5 models in Bosch IDS Light, Bosch IDS Premium Connected
Other codes on the same units
- b2 Indoor T2 sensor fault
- b4 Indoor refrigerant sensor communication fault
- b5 Indoor to outdoor communication fault
- b7 R-454B refrigerant leak protection
- b8 Refrigerant sensor past service life
- C3 T3 coil sensor not reading correctly in cooling
- E7 T5 discharge sensor not reading correctly
- E41 T3 temperature sensor fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch IDS Light installation BTC 762003308 D (02.2025), Fault Code Table 23 and 17.12 Error Code Troubleshooting, p.42-59; Bosch IDS Premium Connected installation BTC 762003301 D (02.2025), Fault Code Table 22 and 18.12 Error Code Troubleshooting. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.