Goodman air conditioner error codes

53 codes (50 faults, 3 normal display and menu codes).

CodeMeaningSeverity / type
01Low side fault or low pressure switch tripHigh
02High side fault or high pressure switch tripHigh
03Short cyclingMedium
04Locked rotorCritical
05Open circuit - compressor off over 4 hoursHigh
06Open start circuitCritical
07Open run circuitCritical
08No line voltageHigh
09Low 24 V control voltageMedium
b0Indoor blower not running when it should beHigh
b9Indoor airflow lower than requestedMedium
d0No shared data on the networkHigh
d1Invalid shared data on the networkHigh
d2System mismatch - indoor unit cannot supply required airflowMedium
d3Configuration mismatch - shared data does not match hardwareHigh
d4Shared data from the loader rejectedHigh
E5Outdoor control low-voltage fuse openHigh
L1Lockout - low pressure switch tripped 3 timesHigh
L2Lockout - high pressure switch tripped 3 timesHigh
L7Lockout - open run circuit detected 4 timesCritical
L8Low line voltageHigh
P0Compressor protector openHigh
Comfort Alert 1Yellow ALERT 1 flash - long run timeMedium
Comfort Alert 2Yellow ALERT 2 flashes - system pressure tripHigh
Comfort Alert 3Yellow ALERT 3 flashes - short cyclingMedium
Comfort Alert 4Yellow ALERT 4 flashes - locked rotorCritical
Comfort Alert 5Yellow ALERT 5 flashes - open circuitHigh
Comfort Alert 6Yellow ALERT 6 flashes - open start circuitCritical
Comfort Alert 7Yellow ALERT 7 flashes - open run circuitCritical
Comfort Alert 9Yellow ALERT 9 flashes - low control voltageMedium
Comfort Alert POWERGreen POWER - module has powerNormal status
Comfort Alert TRIPRed TRIP LED - call present but compressor not runningHigh
Comfort Alert TRIP+ALERTTRIP and ALERT LEDs flashing together - control voltage too lowMedium
Comfort Alert last alert recallLast alert code replayed after power-upNormal status
CoreSense 1Yellow 1 flash - long run time (low side)Medium
CoreSense 2Pressure trip - yellow 2 flashes (red 2 = lockout)High
CoreSense 3Short cycling / pressure switch cycling - yellow 3 (red 3 = lockout)Medium
CoreSense 4Locked rotor - yellow 4 (red 4 = lockout)Critical
CoreSense 5Moderate run trip - yellow 5 (red 5 = lockout)High
CoreSense 9Red 9 flashes - PROT output overcurrentHigh
CoreSense solid redSolid red TRIP - call present but compressor not runningHigh
CoreSense solid yellowSolid yellow RUN - module powered, operating normallyNormal status
EEOutdoor control fault - compressor relay contacts weldedHigh
Yellow 1 flashLow side fault / low pressure trip / low pressure lockout (older ComfortNet board)High
Yellow 2 flashesHigh side fault / high pressure trip / high pressure lockout (older ComfortNet board)High
Yellow 3 flashesShort cycling (older ComfortNet board)Medium
Yellow 4 flashesLocked rotor (older ComfortNet board)Critical
Yellow 5 flashesOpen circuit (older ComfortNet board)High
Yellow 6 flashesOpen start circuit / lockout (older ComfortNet board)Critical
Yellow 7 flashesOpen run circuit / lockout (older ComfortNet board)Critical
Yellow 8 flashesLow or high line voltage (older ComfortNet board)High
Yellow 9 flashesLow 24 V control voltage (older ComfortNet board)Medium
Yellow ON + Red ONCompressor protector open (older ComfortNet board)High

Models covered

ALXS3BN**10AAALXS4BA**10AAALXS4NA**10AAALXS5BA**10AAANX130181ANX130241ANX130301ANX130361ANX130421ANX130481ANX130601ANX130611ANX140181ANX140191ANX140241ANX140251ANX140301ANX140361ANX140371ANX140421ANX140431ANX140481ANX140601ASX130181ASX130241ASX130301ASX130361ASX130421ASX130481ASX130601ASX130611ASX140181ASX140191ASX140241ASX140251ASX140301ASX140311ASX140361ASX140371ASX140421ASX140431ASX140481ASX140601ASX160181ASX160241ASX160301ASX160311ASX160361ASX160371ASX160421ASX160481ASX160601ASX160611ASX180**1ABASXC160241ASXC160361ASXC160481ASXC160601ASXC180241ASXC180361ASXC180481ASXC180601ASXH5***10DSX160241DSX160361DSXC160241DSXC160361DSXC160481DSXC160601DSXC180361DSXC180481DSXC180601GLXS3BN**10AAGLXS4BA**10AAGLXS4MA**10AAGLXS5BA**10AAGSX110903GSX110904GSX111203GSX111204GSX130181GSX130241GSX130301GSX130361GSX130363GSX130371GSX130421GSX130481GSX130483GSX130484GSX130601GSX130603GSX130604GSX130611GSX140181GSX140191GSX140241GSX140251GSX140301GSX140311GSX140361GSX140371GSX140421GSX140431GSX140481GSX140601GSX160181GSX160241GSX160301GSX160311GSX160361GSX160371GSX160421GSX160481GSX160601GSX160611GSX16A181GSX16A241GSX16A301GSX16A361

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.