Goodman air conditioner error codes

52 codes with causes and test steps.

CodeMeaningSeverity
01Low side fault or low pressure switch tripHigh
02High side fault or high pressure switch tripHigh
03Short cyclingMedium
04Locked rotorCritical
05Open circuit - compressor off over 4 hoursHigh
06Open start circuitCritical
07Open run circuitCritical
08No line voltageHigh
09Low 24 V control voltageMedium
b0Indoor blower not running when it should beHigh
b9Indoor airflow lower than requestedMedium
d0No shared data on the networkHigh
d1Invalid shared data on the networkHigh
d2System mismatch - indoor unit cannot supply required airflowMedium
d3Configuration mismatch - shared data does not match hardwareHigh
d4Shared data from the loader rejectedHigh
E5Outdoor control low-voltage fuse openHigh
H8High line voltageHigh
L1Lockout - low pressure switch tripped 3 timesHigh
L2Lockout - high pressure switch tripped 3 timesHigh
L6Lockout - open start circuit detected 4 timesCritical
L7Lockout - open run circuit detected 4 timesCritical
L8Low line voltageHigh
P0Compressor protector openHigh
Comfort Alert 1Yellow ALERT 1 flash - long run timeMedium
Comfort Alert 2Yellow ALERT 2 flashes - system pressure tripHigh
Comfort Alert 3Yellow ALERT 3 flashes - short cyclingMedium
Comfort Alert 4Yellow ALERT 4 flashes - locked rotorCritical
Comfort Alert 5Yellow ALERT 5 flashes - open circuitHigh
Comfort Alert 6Yellow ALERT 6 flashes - open start circuitCritical
Comfort Alert 7Yellow ALERT 7 flashes - open run circuitCritical
Comfort Alert 9Yellow ALERT 9 flashes - low control voltageMedium
Comfort Alert TRIPRed TRIP LED - call present but compressor not runningHigh
Comfort Alert TRIP+ALERTTRIP and ALERT LEDs flashing together - control voltage too lowMedium
CoreSense 1Yellow 1 flash - long run time (low side)Medium
CoreSense 2Pressure trip - yellow 2 flashes (red 2 = lockout)High
CoreSense 3Short cycling / pressure switch cycling - yellow 3 (red 3 = lockout)Medium
CoreSense 4Locked rotor - yellow 4 (red 4 = lockout)Critical
CoreSense 5Moderate run trip - yellow 5 (red 5 = lockout)High
CoreSense 9Red 9 flashes - PROT output overcurrentHigh
CoreSense solid redSolid red TRIP - call present but compressor not runningHigh
EEOutdoor control fault - compressor relay contacts weldedHigh
Yellow 1 flashLow side fault / low pressure trip / low pressure lockout (older ComfortNet board)High
Yellow 2 flashesHigh side fault / high pressure trip / high pressure lockout (older ComfortNet board)High
Yellow 3 flashesShort cycling (older ComfortNet board)Medium
Yellow 4 flashesLocked rotor (older ComfortNet board)Critical
Yellow 5 flashesOpen circuit (older ComfortNet board)High
Yellow 6 flashesOpen start circuit / lockout (older ComfortNet board)Critical
Yellow 7 flashesOpen run circuit / lockout (older ComfortNet board)Critical
Yellow 8 flashesLow or high line voltage (older ComfortNet board)High
Yellow 9 flashesLow 24 V control voltage (older ComfortNet board)Medium
Yellow ON + Red ONCompressor protector open (older ComfortNet board)High

Models covered

ALXS3BN**10AAALXS4BA**10AAALXS4NA**10AAALXS5BA**10AAANX130181ANX130241ANX130301ANX130361ANX130421ANX130481ANX130601ANX130611ANX140181ANX140191ANX140241ANX140251ANX140301ANX140361ANX140371ANX140421ANX140431ANX140481ANX140601ASX130181ASX130241ASX130301ASX130361ASX130421ASX130481ASX130601ASX130611ASX140181ASX140191ASX140241ASX140251ASX140301ASX140311ASX140361ASX140371ASX140421ASX140431ASX140481ASX140601ASX160181ASX160241ASX160301ASX160311ASX160361ASX160371ASX160421ASX160481ASX160601ASX160611ASX180**1ABASXC160241ASXC160361ASXC160481ASXC160601ASXC180241ASXC180361ASXC180481ASXC180601ASXH5***10DSX160241DSX160361DSXC160241DSXC160361DSXC160481DSXC160601DSXC180361DSXC180481DSXC180601GLXS3BN**10AAGLXS4BA**10AAGLXS4MA**10AAGLXS5BA**10AAGSX110903GSX110904GSX111203GSX111204GSX130181GSX130241GSX130301GSX130361GSX130363GSX130371GSX130421GSX130481GSX130483GSX130484GSX130601GSX130603GSX130604GSX130611GSX140181GSX140191GSX140241GSX140251GSX140301GSX140311GSX140361GSX140371GSX140421GSX140431GSX140481GSX140601GSX160181GSX160241GSX160301GSX160311GSX160361GSX160371GSX160421GSX160481GSX160601GSX160611GSX16A181GSX16A241GSX16A301GSX16A361

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.