Goodman · Air conditioner
CoreSense solid yellow Solid yellow RUN - module powered, operating normally
What the display is showing
The CoreSense module on the compressor shows a steady yellow RUN light when it has power and sees normal operation, with no trip. Nothing to fix. A flashing yellow light is an alert and a red light is a trip or lockout.
Applies to: ASX/DSX/GSX and GLXS/ALXS condensing units with CoreSense
Models that show this code
150 models in Goodman/Amana R-32 GLXS/ALXS, Goodman/Amana R-410A GSX/ASX/DSX (ANX/SSX/VSX)
Other codes on the same units
- Comfort Alert last alert recall Last alert code replayed after power-up
- CoreSense 1 Yellow 1 flash - long run time (low side)
- CoreSense 2 Pressure trip - yellow 2 flashes (red 2 = lockout)
- CoreSense 3 Short cycling / pressure switch cycling - yellow 3 (red 3 = lockout)
- CoreSense 4 Locked rotor - yellow 4 (red 4 = lockout)
- CoreSense 5 Moderate run trip - yellow 5 (red 5 = lockout)
- CoreSense 9 Red 9 flashes - PROT output overcurrent
- CoreSense solid red Solid red TRIP - call present but compressor not running
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: GSX/GSZ service RS6200006r103, CoreSense Diagnostics Table p.76 and Quick Reference Table 1 p.78; R-32 GLXS/GLZS service RS6200301, CoreSense Diagnostics Table p.21. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.