Goodman · Air conditioner
Comfort Alert last alert recall Last alert code replayed after power-up
What the display is showing
After the module is powered on, it shows the last stored alert flash code for 1 minute. A code seen right after power-up can therefore be an old alert and not a present one. The LED shows the flash count, a pause, then repeats.
Applies to: ASX130[18-60]CA, ASX140[18-36]1CA, ASX140421DA, ASX140[48-60]1BA with 2-wire module
Models that show this code
142 models in Goodman/Amana R-410A GSX/ASX/DSX (ANX/SSX/VSX)
Other codes on the same units
- Comfort Alert 9 Yellow ALERT 9 flashes - low control voltage
- Comfort Alert POWER Green POWER - module has power
- Comfort Alert TRIP Red TRIP LED - call present but compressor not running
- Comfort Alert TRIP+ALERT TRIP and ALERT LEDs flashing together - control voltage too low
- CoreSense 1 Yellow 1 flash - long run time (low side)
- CoreSense 2 Pressure trip - yellow 2 flashes (red 2 = lockout)
- CoreSense 3 Short cycling / pressure switch cycling - yellow 3 (red 3 = lockout)
- CoreSense 4 Locked rotor - yellow 4 (red 4 = lockout)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: GSX/GSZ service RS6200006r103, Diagnostics Table: 2-Wire Comfort Alert Module p.74-75. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.