Goodman · Air conditioner

Comfort Alert 1 Yellow ALERT 1 flash - long run time

Medium severity Goodman/Amana R-410A GSX/ASX/DSX (ANX/SSX/VSX)

What the control is telling you

Compressor is running extremely long cycles, typical of low capacity.

Applies to: Amana ASX13 (CA revision) and ASX14 (1CA, 1BA and 421DA revisions) condensers fitted with the 2-wire Comfort Alert module

Likely causes

  • Low refrigerant charge
  • Indoor blower not running
  • Frozen indoor coil
  • Metering device fault
  • Dirty outdoor coil
  • Restricted liquid line or drier
  • Thermostat fault

Test and repair steps

  1. Check refrigerant charge (superheat / subcooling) and look for leaks.
  2. Confirm indoor blower operation, clean filters and coil; thaw an iced coil before testing.
  3. Check the metering device (TXV bulb, piston).
  4. Check the liquid line drier for a temperature drop.
  5. Clean the outdoor coil and check the thermostat.

Models that show this code

142 models in Goodman/Amana R-410A GSX/ASX/DSX (ANX/SSX/VSX)

ANX130181ANX130241ANX130301ANX130361ANX130421ANX130481ANX130601ANX130611ANX140181ANX140191ANX140241ANX140251ANX140301ANX140361ANX140371ANX140421ANX140431ANX140481ANX140601ASX130181ASX130241ASX130301ASX130361ASX130421ASX130481ASX130601ASX130611ASX140181ASX140191ASX140241ASX140251ASX140301ASX140311ASX140361ASX140371ASX140421ASX140431ASX140481ASX140601ASX160181ASX160241ASX160301ASX160311ASX160361ASX160371ASX160421ASX160481ASX160601ASX160611ASX180**1ABASXH5***10DSX160241DSX160361GSX110903GSX110904GSX111203GSX111204GSX130181GSX130241GSX130301

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman RS6200006r103 R-410A ASX/GSX/DSX/ASZ/GSZ/DSZ service (text export) - Goodman_R_410A_ASX_GSX_DSX_A_C_and_ASZ_GSZ_DSZ_HP_covers_GSX_GSZ_lines_GSXH5_GSZH5_service.txt - section Diagnostics Table: 2-Wire Comfort Alert Module. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.