York furnace error codes

20 codes with causes and test steps, plus 2 settings tables.

CodeMeaningSeverity
1 red flashFlame detected with gas valve offCritical
2 red flashesPressure switch closed when it should be openMedium
3 amber flashesW2 call without W1Low
3 double red flashesSecond-stage pressure switch not closingMedium
3 red flashesPressure switch open when it should be closedHigh
4 amber flashesCooling call (Y) without fan call (G)Low
4 red flashesMain limit switch openHigh
5 red flashesRollout switch open / limit circuit open over 15 minCritical
6 red flashesPressure switch cycling lockoutMedium
7 red flashesIgnition failure lockout (retries)High
8 red flashesFlame lost repeatedly (recycles)High
9 red flashesPolarity reversed or bad groundMedium
10 red flashesGas valve powered with no heat callCritical
11 red flashesLimit open 5-15 minutes - blower failureHigh
12 red flashesHot surface igniter open / igniter failureHigh
13 red flashesHigh-fire pressure switch openMedium
LED steady offBoard LED dark - no power to controlHigh
Rapid amber flashWeak flame signalMedium
Rapid red flashTwinning error or wrong 24 V phasingMedium
Steady on (any color)LED lit solid - internal control faultHigh

Settings and specs

Clearance to combustibles

Clearances · York TM9V

Side of furnaceUpflowDownflowHorizontal
Top / vent / rear / side / front???
Combustible floorYesYes (special sub-base only)Yes
ClosetYesYesYes
Line contactNoNoYes
  • Leave about 24 in. at the front and 18 in. at the side for service.
  • Approved for alcove and attic installs.
  • Inch clearances could not be rebuilt from the text export (cells run together; only 0 in. and 1 in. values appear) - read them off the unit label.

Source: York TM9V - -M9V 96% two-stage variable speed installation 1083294-UIM-A-0114.pdf - section Table 1 Unit Clearances to Combustibles

Filter size by return location

Filters · York TM9V

AirflowCabinetSide return filterBottom return filter
1000 CFMA16 x 25 in.14 x 25 in.
1200 CFMB16 x 25 in.16 x 25 in.
1600 CFMC16 x 25 in.20 x 25 in.
2000 CFMC(2) 16 x 25 in.20 x 25 in.
2000 CFMD(2) 16 x 25 in.22 x 25 in.
  • Sizes assume high velocity filters (600 FPM); throwaway filters must stay at or below 300 FPM.
  • Filters go outside the cabinet - never inside the furnace.
  • A single side return with one 16 x 25 filter is good to 1800 CFM; above that use two side returns, side + bottom, or a transition to a 20 x 25 filter.

Source: York TM9V - -M9V 96% two-stage variable speed installation 1083294-UIM-A-0114.pdf - section Table 4 Recommended Filter Sizes

Models covered

TM9V040A10TM9V060B12TM9V080B12TM9V080C16TM9V100C16TM9V100C20TM9V120D20

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.