York · Furnace
2 amber flashes Normal - call for second-stage heat
What the display is showing
Two amber flashes mean the control sees a call for second-stage heat and is running normally. Only present on two-stage boards.
Applies to: Two-stage White-Rodgers/Emerson and UTEC IFC boards
Settings for these units
- Clearance to combustibles · York TM9V
- Filter size by return location · York TM9V
Other codes on the same units
- 1 amber flash Normal - call for heat, first stage on
- 1 red flash Flame detected with gas valve off
- 2 green flashes No stored fault codes
- 2 red flashes Pressure switch closed when it should be open
- 3 amber flashes W2 call without W1
- 3 double red flashes Second-stage pressure switch not closing
- 3 green flashes Fault memory cleared
- 3 red flashes Pressure switch open when it should be closed
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: York service letter ST-028-07 White Rodgers/Emerson IFC boards, Fault Code Sheet, p.5-7; York service tip ST-045-09 UTEC IFC boards, Fault Code Sheet. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.