York · Furnace
3 amber flashes W2 call without W1
What the control is telling you
Two-stage boards only: the control sees a second-stage heat call with no first-stage call.
Applies to: York/JCI residential gas furnaces: York UTEC IFC furnaces, York White-Rodgers IFC furnaces
Likely causes
- Thermostat wired to W2 only
- Broken or loose W1 wire
- Thermostat configuration error
Test and repair steps
- Check the thermostat wiring at W1 and W2 on the board.
- Make sure the thermostat energizes W1 whenever it calls W2.
- Repair any broken W1 conductor.
Settings for these units
- Clearance to combustibles · York TM9V
- Filter size by return location · York TM9V
Other codes on the same units
- 1 red flash Flame detected with gas valve off
- 2 amber flashes Normal - call for second-stage heat
- 2 green flashes No stored fault codes
- 2 red flashes Pressure switch closed when it should be open
- 3 double red flashes Second-stage pressure switch not closing
- 3 green flashes Fault memory cleared
- 3 red flashes Pressure switch open when it should be closed
- 4 amber flashes Cooling call (Y) without fan call (G)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: York All JCI single-two-stage furnaces with UTEC IFC board codes ST-045-09.pdf - section Fault Code LED Flashes; York JCI single-two-stage furnaces with White-Rodgers-Emerson IFC (older installed base) codes ST-028-07.pdf - section Fault Code Sheets. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.