Daikin air handler error codes

19 codes (18 faults, 1 normal display and menu code).

CodeMeaningSeverity / type
9bLow indoor airflow (with electric heat)Medium
70EEV disconnection detectedHigh
73Liquid side thermistor abnormalityMedium
74Gas side thermistor abnormalityMedium
75Pressure sensor abnormalityMedium
76Indoor unit to outdoor unit / gas furnace / blower communication error (during operation)High
77Indoor unit to thermostat communication error (start-up and during operation)Medium
78Indoor unit to outdoor unit / gas furnace / blower communication error (start-up operation)High
b4Blower motor current trip or lost rotorMedium
b7ID blower motor missing required parameters, fails to startHigh
b9Low indoor airflow (without electric heat)Medium
E76No outdoor unit or indoor unit communicationHigh
E77No thermostat communicationMedium
E78No outdoor unit or indoor unit communicationHigh
Eb0Estimated indoor airflow near zero CFMHigh
Eb9Indoor airflow below requirementMedium
Ed2System mismatchMedium
EEEmergency operation indicatorNormal status
EdElectric heater DIP switches not matched to heater kitLow

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.