Goodman air handler error codes

42 codes (15 faults, 27 normal display and menu codes).

CodeMeaningSeverity / type
1ACCompressor cooling, low stage (non-comm)Normal status
2aCCompressor cooling, high stage (non-comm)Normal status
5rShared data revisionMenu / mode display
AC1Compressor cooling, low stage (comm)Normal status
AC2Compressor cooling, high stage (comm)Normal status
df1Defrost, low-stage electric heatNormal status
df2Defrost, high-stage electric heatNormal status
E05Air handler fuse openHigh
Eb0Blower motor not running with a demand presentHigh
Eb1Control lost communication with the blower motorHigh
Eb2Motor horsepower does not match shared dataHigh
Eb4Blower motor lost rotor control or high currentHigh
Eb5Blower motor failed to start 10 timesHigh
Eb6Blower shut down for voltage or power module temperatureHigh
Eb7Blower motor missing shared data / failed to start 40 timesHigh
Eb9Airflow lower than demandedMedium
EC1Communication error with the outdoor unitHigh
Ed1Invalid shared dataHigh
Ed4Shared data rejected by the controlHigh
HP1Compressor heat, low stage (comm)Normal status
HP2Compressor heat, high stage (comm)Normal status
Ht1Electric heat (Ht1)Normal status
Ht2Electric heat, high stageNormal status
L6FFault recall (furnace-type menu)Menu / mode display
ACCompressor cooling, single stage (non-comm)Normal status
AxxAirflow readout (A08 = 800 CFM)Normal status
CrControl firmware revisionMenu / mode display
FAnConstant fanNormal status
FCLFault recall (outdoor communicating units)Menu / mode display
Flashing optionMenu option flashing = not yet selectedMenu / mode display
HPCompressor heat, single stageNormal status
HtElectric heat, single stageNormal status
IdlIdle - no callNormal status
LrnRestart indoor-outdoor communicationMenu / mode display
RDS 4 flashesR32 sensor internal faultHigh
RDS fast flashR-32 leak alarm (or system verification test)Critical
RDS slow flashNormal operation - leak detection OKNormal status
RDS steady onDelay mode after leak alarm or faultMedium
RDS test modeSystem verification test (simulated leak)Menu / mode display
Rx LED rapid flashGreen receive LED rapid flashing - normal network trafficNormal status
dHUDehumidificationNormal status
dftDefrost, single-stage electric heat (non-comm)Normal status

Models covered

ACSF****13**AAAMST***U1300AAAVPTC183014AVPTC25B14AVPTC29B14AVPTC313714AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC426014AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AWSF****13**AAAWST****13**AAMBVC1201MBVC1601MBVC2001

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.