Goodman air handler error codes
42 codes (15 faults, 27 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 1AC | Compressor cooling, low stage (non-comm) | Normal status |
| 2aC | Compressor cooling, high stage (non-comm) | Normal status |
| 5r | Shared data revision | Menu / mode display |
| AC1 | Compressor cooling, low stage (comm) | Normal status |
| AC2 | Compressor cooling, high stage (comm) | Normal status |
| df1 | Defrost, low-stage electric heat | Normal status |
| df2 | Defrost, high-stage electric heat | Normal status |
| E05 | Air handler fuse open | High |
| Eb0 | Blower motor not running with a demand present | High |
| Eb1 | Control lost communication with the blower motor | High |
| Eb2 | Motor horsepower does not match shared data | High |
| Eb4 | Blower motor lost rotor control or high current | High |
| Eb5 | Blower motor failed to start 10 times | High |
| Eb6 | Blower shut down for voltage or power module temperature | High |
| Eb7 | Blower motor missing shared data / failed to start 40 times | High |
| Eb9 | Airflow lower than demanded | Medium |
| EC1 | Communication error with the outdoor unit | High |
| Ed1 | Invalid shared data | High |
| Ed4 | Shared data rejected by the control | High |
| HP1 | Compressor heat, low stage (comm) | Normal status |
| HP2 | Compressor heat, high stage (comm) | Normal status |
| Ht1 | Electric heat (Ht1) | Normal status |
| Ht2 | Electric heat, high stage | Normal status |
| L6F | Fault recall (furnace-type menu) | Menu / mode display |
| AC | Compressor cooling, single stage (non-comm) | Normal status |
| Axx | Airflow readout (A08 = 800 CFM) | Normal status |
| Cr | Control firmware revision | Menu / mode display |
| FAn | Constant fan | Normal status |
| FCL | Fault recall (outdoor communicating units) | Menu / mode display |
| Flashing option | Menu option flashing = not yet selected | Menu / mode display |
| HP | Compressor heat, single stage | Normal status |
| Ht | Electric heat, single stage | Normal status |
| Idl | Idle - no call | Normal status |
| Lrn | Restart indoor-outdoor communication | Menu / mode display |
| RDS 4 flashes | R32 sensor internal fault | High |
| RDS fast flash | R-32 leak alarm (or system verification test) | Critical |
| RDS slow flash | Normal operation - leak detection OK | Normal status |
| RDS steady on | Delay mode after leak alarm or fault | Medium |
| RDS test mode | System verification test (simulated leak) | Menu / mode display |
| Rx LED rapid flash | Green receive LED rapid flashing - normal network traffic | Normal status |
| dHU | Dehumidification | Normal status |
| dft | Defrost, single-stage electric heat (non-comm) | Normal status |
Models covered
ACSF****13**AAAMST***U1300AAAVPTC183014AVPTC25B14AVPTC29B14AVPTC313714AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC426014AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AWSF****13**AAAWST****13**AAMBVC1201MBVC1601MBVC2001
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.