Goodman · Air handler
RDS slow flash Normal operation - leak detection OK
What the display is showing
The red LED on the leak detection (RDS) board flashes slowly, about 2 seconds on and 2 seconds off, when the R-32 detection system is healthy and no leak is sensed. It can be seen through the round glass window in the top access panel. No action is needed. The unit must stay powered except during service.
Applies to: AMST/AWSF/ACSF R-32 air handlers
Models that show this code
4 models in Goodman/Amana R-32 AMST/AWSF/ACSF air handlers
Other codes on the same units
- RDS 4 flashes R32 sensor internal fault
- RDS fast flash R-32 leak alarm (or system verification test)
- RDS steady on Delay mode after leak alarm or fault
- RDS test mode System verification test (simulated leak)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: R-32 GLXS/GLZS and AMST/AWSF service RS6200301, RDS A2L PCB FAULT CODE table p.25 and Recommended Action table p.26. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.