Goodman · Air handler

Ed4 Shared data rejected by the control

High severity Goodman/Amana ComfortBridge AVPTC/MBVC

What the control is telling you

The control refused the shared data on the BTSDL01 loader; operation may differ from expected or not run.

Applies to: ComfortBridge communicating air handlers AVPTC**14 (B* revision board) and MBVC1201/1601/2001 modular blowers

Likely causes

  • Loader data does not match this model

Test and repair steps

  1. Verify the loader holds data for this exact model.
  2. Check the model number on the air handler rating plate.
  3. Load the correct shared data for this air handler model with the Bluetooth Shared Data Loader BTSDL01.
  4. Insert the loader before power-up; remove it only after power is off.

Models that show this code

21 models in Goodman/Amana ComfortBridge AVPTC/MBVC

AVPTC183014AVPTC25B14AVPTC29B14AVPTC313714AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC426014AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14MBVC1201MBVC1601MBVC2001

Other codes on the same units

  • Eb7 Blower motor missing shared data / failed to start 40 times
  • Eb9 Airflow lower than demanded
  • EC1 Communication error with the outdoor unit
  • Ed1 Invalid shared data
  • HP1 Compressor heat, low stage (comm)
  • HP2 Compressor heat, high stage (comm)
  • Ht1 Electric heat (Ht1)
  • Ht2 Electric heat, high stage

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Air Handler Troubleshooting Matrix (B*) p.59-60. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.