Goodman · Air handler
Eb9 Airflow lower than demanded
What the control is telling you
Delivered airflow is below the requested value; the system may perform poorly or run low stage when high stage is expected.
Applies to: ComfortBridge communicating air handlers AVPTC**14 (B* revision board) and MBVC1201/1601/2001 modular blowers
Likely causes
- Blocked filters or restrictive ductwork
- Undersized ductwork
Test and repair steps
- Clean or replace filters and clear obstructions.
- Check for blocked ducts and closed registers.
- Verify duct sizing; resize or replace ductwork if necessary.
Models that show this code
21 models in Goodman/Amana ComfortBridge AVPTC/MBVC
Other codes on the same units
- Eb4 Blower motor lost rotor control or high current
- Eb5 Blower motor failed to start 10 times
- Eb6 Blower shut down for voltage or power module temperature
- Eb7 Blower motor missing shared data / failed to start 40 times
- EC1 Communication error with the outdoor unit
- Ed1 Invalid shared data
- Ed4 Shared data rejected by the control
- HP1 Compressor heat, low stage (comm)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Air Handler Troubleshooting Matrix (B*) p.59-60. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.