Goodman · Air handler
dft Defrost, single-stage electric heat (non-comm)
What the display is showing
Shown during defrost with single-stage electric heat and a non-communicating heat pump. With a legacy-wired heat pump, dft also appears when the heat pump asks for auxiliary heat, because Y and W are energized in both cases. Not a fault.
Applies to: AVPTC / MBVC ComfortBridge air handlers
Models that show this code
21 models in Goodman/Amana ComfortBridge AVPTC/MBVC
Other codes on the same units
- FCL Fault recall (outdoor communicating units)
- Flashing option Menu option flashing = not yet selected
- HP Compressor heat, single stage
- Ht Electric heat, single stage
- Idl Idle - no call
- Lrn Restart indoor-outdoor communication
- Rx LED rapid flash Green receive LED rapid flashing - normal network traffic
- dHU Dehumidification
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Goodman ComfortNet ASXC-DSXC-GSXC / ASZC-DSZC-GSZC / AVPTC-MBVC service, Air Handler Display (B*) system status table p.63. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.