Bosch boiler error codes
49 codes (18 faults, 31 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 000-199 | Supply temperature readout | Normal status |
| 2.C | Service function 2.C - purging function | Menu / mode display |
| 2.F | Service function 2.F - temporary test operating mode | Menu / mode display |
| 4.E | Service function 4.E - appliance type detected | Menu / mode display |
| 4.F | Service function 4.F - trap filling routine | Menu / mode display |
| 5.A | Service function 5.A - reset service-due indication | Menu / mode display |
| 6.A | Service function 6.A - latest fault code | Menu / mode display |
| 6.C | Service function 6.C - target supply temperature from outdoor reset | Menu / mode display |
| 6.b | Service function 6.b - room control voltage at terminal 2 | Menu / mode display |
| 6.d | Service function 6.d - DHW turbine flow rate | Menu / mode display |
| 7.A | Service function 7.A - burner and fault indicator lamp | Menu / mode display |
| 7.E | Service function 7.E - building drying function | Menu / mode display |
| 7.b | Service function 7.b - 3-way valve to center position | Menu / mode display |
| 8.A | Service function 8.A - software version | Menu / mode display |
| 8.C | Service function 8.C - gas burner control (GFA) status | Menu / mode display |
| 8.E | Service function 8.E - restore factory settings | Menu / mode display |
| 8.F | Service function 8.F - permanent ignition test | Menu / mode display |
| 8.b | Service function 8.b - code plug number | Menu / mode display |
| 8.d | Service function 8.d - gas burner control (GFA) fault | Menu / mode display |
| 9.A | Service function 9.A - constant operating mode | Menu / mode display |
| 9.C | Service function 9.C - current boiler output | Menu / mode display |
| 9.b | Service function 9.b - current fan speed | Menu / mode display |
| A7 | DHW temperature sensor fault | Medium |
| A8 | Communication fault | Medium |
| b1 | Code plug not detected | Medium |
| b2/b3/b4/b5/b6 | Internal data error | Medium |
| b7 | Burner control fault | Medium |
| C6 | Fan not running | High |
| d3 | High limit / temperature limiter circuit open | High |
| d5 | External supply temperature sensor fault (low-loss header) | Medium |
| E2 | Supply temperature sensor fault | High |
| E3 | Additional supply temperature sensor fault | Medium |
| E9 | Safety high limit or flue gas limiter tripped | High |
| F0 | Internal fault | Medium |
| F1 | Internal data error | Medium |
| F7 | Flame detected with burner off | High |
| A.C | Service function A.C - DHW tank temperature | Menu / mode display |
| A.b | Service function A.b - DHW temperature | Menu / mode display |
| Ad | DHW tank temperature not detected | Medium |
| C.d | Service function C.d - current heat demand | Menu / mode display |
| DHW setpoint flashing | Set DHW temperature flashing on display | Normal status |
| Display off | Display dark - appliance switched off | Normal status |
| EA | No flame detected | High |
| ECO button lit | ECO button lit - economy / alternating mode | Normal status |
| Emissions test button | Emissions test (chimney sweep) button | Menu / mode display |
| FA | Flame detected after gas shut off | Critical |
| Fd | Reset button pressed by mistake | Low |
| Key pad lock button | Key pad lock | Menu / mode display |
| Service button | Service button - open service functions | Menu / mode display |
Models covered
ZBR21-3AZBR28-3AZBR35-3AZBR42-3A
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.