Bosch · Boiler
4.E Service function 4.E - appliance type detected
What the display is showing
Shows the type of appliance the control has detected. 00 heating only, 01 combi, 02 DHW tank temperature sensor connected, 03 DHW tank thermostat connected, 04 stratified tank, 05 tank fitted with an NTC return sensor. Read-only.
Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis
What to do
- Open service functions with the service button, scroll with the key pad lock / ECO buttons
- Select 4.E to read the value
Models that show this code
4 models in Bosch Greenstar
Other codes on the same units
- 000-199 Supply temperature readout
- 2.C Service function 2.C - purging function
- 2.F Service function 2.F - temporary test operating mode
- 4.F Service function 4.F - trap filling routine
- 5.A Service function 5.A - reset service-due indication
- 6.A Service function 6.A - latest fault code
- 6.C Service function 6.C - target supply temperature from outdoor reset
- 6.b Service function 6.b - room control voltage at terminal 2
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.3 Description of the service functions pp.59-64. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.