Bosch · Boiler

2.F Service function 2.F - temporary test operating mode

Menu / mode display Bosch Greenstar

What the display is showing

Temporarily forces output: 00 normal, 01 holds minimum output for 15 minutes, 02 holds maximum output for 15 minutes. The display reads 2.F while it is active and the boiler goes back to normal after 15 minutes or when the function is aborted.

Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis

What to do

  1. Open service functions with the service button, scroll with the key pad lock / ECO buttons
  2. Select 2.F, choose 01 or 02, save

Models that show this code

4 models in Bosch Greenstar

ZBR21-3AZBR28-3AZBR35-3AZBR42-3A

Other codes on the same units

  • 000-199 Supply temperature readout
  • 2.C Service function 2.C - purging function
  • 4.E Service function 4.E - appliance type detected
  • 4.F Service function 4.F - trap filling routine
  • 5.A Service function 5.A - reset service-due indication
  • 6.A Service function 6.A - latest fault code
  • 6.C Service function 6.C - target supply temperature from outdoor reset
  • 6.b Service function 6.b - room control voltage at terminal 2

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.3 Description of the service functions pp.59-64. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.