Bosch · Boiler

9.b Service function 9.b - current fan speed

Menu / mode display Bosch Greenstar

What the display is showing

Displays the present fan speed in revolutions per second. Read-only.

Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis

What to do

  1. Reach the second level and scroll to 9.b

Models that show this code

4 models in Bosch Greenstar

ZBR21-3AZBR28-3AZBR35-3AZBR42-3A

Other codes on the same units

  • 8.b Service function 8.b - code plug number
  • 8.d Service function 8.d - gas burner control (GFA) fault
  • 9.A Service function 9.A - constant operating mode
  • 9.C Service function 9.C - current boiler output
  • A7 DHW temperature sensor fault
  • A8 Communication fault
  • b1 Code plug not detected
  • b2/b3/b4/b5/b6 Internal data error

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.3 Description of the service functions pp.59-64. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.