Bosch · Boiler
8.d Service function 8.d - gas burner control (GFA) fault
What the display is showing
Shows an internal fault number of the gas burner control unit, for use with Bosch support.
Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis
What to do
- Reach the second level and scroll to 8.d
Models that show this code
4 models in Bosch Greenstar
Other codes on the same units
- 8.C Service function 8.C - gas burner control (GFA) status
- 8.E Service function 8.E - restore factory settings
- 8.F Service function 8.F - permanent ignition test
- 8.b Service function 8.b - code plug number
- 9.A Service function 9.A - constant operating mode
- 9.C Service function 9.C - current boiler output
- 9.b Service function 9.b - current fan speed
- A7 DHW temperature sensor fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.3 Description of the service functions pp.59-64. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.