Bosch · Boiler
Service button Service button - open service functions
What the display is showing
Keeping the service button pressed until it lights opens the service functions, and the display then shows a function number such as 1.A. Functions up to 0.E are the first level; functions starting with 8.A are the second level, reached by pressing the ECO and key pad lock buttons together. The unit leaves service mode on its own after 15 minutes without a button press. Saving a value is done by holding the emissions test button.
Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis
What to do
- Keep the service button pressed until it lights
- Use the key pad lock button (down) or ECO button (up) to scroll to a function
- Tap the emissions test button to see its value
- Change the value with the same two buttons
- Hold the emissions test button to save, or press it briefly to leave without saving
Models that show this code
4 models in Bosch Greenstar
Other codes on the same units
- DHW setpoint flashing Set DHW temperature flashing on display
- Display off Display dark - appliance switched off
- EA No flame detected
- ECO button lit ECO button lit - economy / alternating mode
- Emissions test button Emissions test (chimney sweep) button
- FA Flame detected after gas shut off
- Fd Reset button pressed by mistake
- Key pad lock button Key pad lock
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.1 Guideline to service functions p.57-58. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.