Lennox air handler error codes

69 codes (67 faults, 2 normal display and menu codes).

CodeMeaningSeverity / type
10Unknown device detectedHigh
11Missing deviceHigh
12Indoor unit not detectedHigh
13Duplicate comfort sensor IDHigh
14Too many devices of the same typeHigh
15Parameter mismatch detectedLow
20Protocol upgrade requiredHigh
21Incompatible equipment detectedHigh
31Lost communication with deviceHigh
32Device resettingLow
34Must program unit capacity for deviceHigh
41Device control board replacedLow
500PureAir differential pressure sensor faultMedium
501PureAir UV sensor faultMedium
502PureAir UV lamp offMedium
503PureAir filter life at 10%Medium
504PureAir filter life at 0%Medium
505PureAir model selection changedMedium
506PureAir lamp at 0% lifeMedium
507PureAir filter calibration failureMedium
530Zoning low damper 24 VACMedium
532Zoning pressure switch opened (high pressure)Low
542Zone 1 temperature sensor faultMedium
543Zone 2 temperature sensor faultMedium
544Zone 3 temperature sensor faultMedium
545Zone 4 temperature sensor faultMedium
546Zone sensor parameters reset after power restoreMedium
547Zone sensor parameters reset from system interruptionMedium
548Zone humidity sensor errorMedium
551Zone sensor lost communicationMedium
71511Duct or filter blockageMedium
71517Indoor fan motor failureHigh
E105Wiring issue / communication problemHigh
E114AC line frequency / distortion problemHigh
E115Low secondary (24 VAC) voltageHigh
E116High secondary (24 VAC) voltageMedium
E117Poor groundMedium
E120Unresponsive deviceMedium
E124Thermostat lost communication to smart hubHigh
E125Control hardware problemHigh
E126Control internal communication problemHigh
E130Configuration jumper missingHigh
E132Device control software faultHigh
E180Outdoor temperature sensor problemMedium
E201Blower motor communication faultHigh
E202Blower motor and unit size mismatchHigh
E203Invalid unit size codeHigh
E292Blower motor start faultHigh
E295Blower motor over temperatureMedium
E310Discharge air temperature sensor problemMedium
E312Reduced airflow - indoor blower cutbackLow
E345Relay O failureHigh
E346Heat pump jumper not removedHigh
E347Indoor or EIM relay Y1 faultHigh
E348Indoor relay Y2 faultMedium
E350Electric heat not configuredHigh
E351Electric heat stage 1 faultHigh
E352Electric heat stage 2 faultMedium
E353Electric heat stage 3 faultMedium
E354Electric heat stage 4 faultMedium
E355Electric heat stage 5 faultMedium
E371Float switch sensed openHigh
E380EIM interlock relay faultHigh
E381EIM interlock relay stuckHigh
E382EIM relay W1 faultHigh
E420EIM defrost out of cycleMedium
--Double dashes - zone sensor problemMedium
=Two bars - soft disableMenu / mode display
Green LED 3 s on / 1 s offSoft disable - zoning damper module or EIMMenu / mode display

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.