Lennox · Air handler
-- Double dashes - zone sensor problem
What the control is telling you
Two dashes shown for indoor temperature on the S30/S40 or zone sensor: loose or miswired connections or two zone sensors on the same zone number. System runs central mode and individual zoning is disabled. S30/S40 thermostat / zone sensor display.
Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems
Likely causes
- Loose or incorrect zone sensor wiring
- Duplicate zone number
Test and repair steps
- Check zone number assignments.
- Check and correct zone sensor wiring.
- Run the re-configuration procedure.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.51. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.